Misplaced Pages

Blalock–Thomas–Taussig shunt: Difference between revisions

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
Browse history interactively← Previous editContent deleted Content addedVisualWikitext
Revision as of 18:25, 6 February 2024 editDicemaze (talk | contribs)13 edits updated instances where the article used the procedure's previous name← Previous edit Latest revision as of 06:01, 5 August 2024 edit undo2a00:23c6:8d23:1b01:dc33:af04:5f61:a6e0 (talk) HistoryTags: Mobile edit Mobile web edit 
(2 intermediate revisions by 2 users not shown)
Line 5: Line 5:
| synonyms = Blalock–Taussig shunt, BTT shunt | synonyms = Blalock–Taussig shunt, BTT shunt
| image = Blalock Taussig Shunt - Aortic to Pulmonary.png | image = Blalock Taussig Shunt - Aortic to Pulmonary.png
| caption = Modified Blalock–Thomas-Taussig Shunt connecting right subclavian artery to pulmonary artery | caption = Modified Blalock–Thomas–Taussig Shunt connecting right subclavian artery to pulmonary artery
| pronounce = | pronounce =
| specialty = ] | specialty = ]
Line 19: Line 19:
}} }}


The '''Blalock–Thomas–Taussig shunt''' ('''BTT shunt'''),<ref>{{Cite journal |last1=Blake |first1=Kathleen |last2=Yancy |first2=Clyde W. |date=2022-04-01 |title=Change the Name of the Blalock–Taussig Shunt to Blalock–Thomas–Taussig Shunt |url=https://doi.org/10.1001/jamasurg.2021.5611 |journal=JAMA Surgery |volume=157 |issue=4 |pages=287–288 |doi=10.1001/jamasurg.2021.5611 |pmid=34964811 |s2cid=245538449 |issn=2168-6254}}</ref> previously known as the '''Blalock-Taussig Shunt''' ('''BT shunt'''),<ref name="mBTT">{{Cite journal |last1=Alahmadi |first1=Mohamed H. |last2=Bishop |first2=Michael A. |date=2023-10-14 |title=Modified Blalock-Taussig-Thomas Shunt |url=https://www.ncbi.nlm.nih.gov/books/NBK597363/ |journal=StatPearls |pmid=37983362}}</ref> is a surgical procedure used to increase blood flow to the lungs in some forms of ]<ref name=":1">{{Cite journal|last1=Yuan|first1=Shi-Min|last2=Shinfeld|first2=Amihay|last3=Raanani|first3=Ehud|date=March 2009|title=The Blalock–Taussig shunt|journal=Journal of Cardiac Surgery|volume=24|issue=2|pages=101–108|doi=10.1111/j.1540-8191.2008.00758.x|issn=1540-8191|pmid=19040408|doi-access=free}}</ref> such as ] and ] and are common causes of ].<ref name=":1" /> The procedure involves connecting a branch of the ] or ] to the ]. In modern practice, this procedure is temporarily used to direct blood flow to the lungs and relieve cyanosis while the infant is waiting for corrective or definitive surgery when their heart is larger. The BTT shunt is used in the first step of the three-stage palliation (the ]). The '''Blalock–Thomas–Taussig shunt''' ('''BTT shunt'''),<ref>{{Cite journal |last1=Blake |first1=Kathleen |last2=Yancy |first2=Clyde W. |date=2022-04-01 |title=Change the Name of the Blalock–Taussig Shunt to Blalock–Thomas–Taussig Shunt |url=https://doi.org/10.1001/jamasurg.2021.5611 |journal=JAMA Surgery |volume=157 |issue=4 |pages=287–288 |doi=10.1001/jamasurg.2021.5611 |pmid=34964811 |s2cid=245538449 |issn=2168-6254}}</ref> previously known as the '''Blalock–Taussig Shunt''' ('''BT shunt'''),<ref name="mBTT">{{Cite journal |last1=Alahmadi |first1=Mohamed H. |last2=Bishop |first2=Michael A. |date=2023-10-14 |title=Modified Blalock-Taussig-Thomas Shunt |url=https://www.ncbi.nlm.nih.gov/books/NBK597363/ |journal=StatPearls |pmid=37983362}}</ref> is a surgical procedure used to increase blood flow to the lungs in some forms of ]<ref name=":1">{{Cite journal|last1=Yuan|first1=Shi-Min|last2=Shinfeld|first2=Amihay|last3=Raanani|first3=Ehud|date=March 2009|title=The Blalock–Taussig shunt|journal=Journal of Cardiac Surgery|volume=24|issue=2|pages=101–108|doi=10.1111/j.1540-8191.2008.00758.x|issn=1540-8191|pmid=19040408|doi-access=free}}</ref> such as ] and ], which are common causes of ].<ref name=":1" /> The procedure involves connecting a branch of the ] or ] to the ]. In modern practice, this procedure is temporarily used to direct blood flow to the lungs and relieve cyanosis while the infant is waiting for corrective or definitive surgery when their heart is larger. The BTT shunt is used in the first step of the three-stage palliation (the ]).


__TOC__ __TOC__


==Alternatives== ==Alternatives==
] ]
While the originally described Blalock–Thomas-Taussig shunt directly connected the subclavian and pulmonary arteries, in contemporary practice a modified version of the procedure, the mBTT shunt, is more commonly used.<ref name="mBTT" /><ref name=":0">{{Cite journal|last1=Kiran|first1=Usha|last2=Aggarwal|first2=Shivani|last3=Choudhary|first3=Arin|last4=Uma|first4=B.|last5=Kapoor|first5=Poonam Malhotra|date=July 2017|title=The Blalock and Taussig Shunt Revisited|journal=Annals of Cardiac Anaesthesia|volume=20|issue=3|pages=323–330|doi=10.4103/aca.ACA_80_17|issn=0974-5181|pmc=5535574|pmid=28701598 |doi-access=free }}</ref> In the modified Blalock–Thomas-Taussig shunt, a length of artificial tubing typically made from ] (]) is sewn between either the subclavian or the carotid artery and the corresponding side branch of the pulmonary artery.<ref name=":0" /> This modification removes the need to cut off blood supply and makes it easier to regulate the blood flow to the lungs. Some centers now use a shunt directly from the right ventricle to the pulmonary artery, a ]. This is done to avoid the reduced diastolic blood flow in the ] associated with the mBTT shunt.{{citation needed|date=June 2020}} While the originally described Blalock–Thomas–Taussig shunt directly connected the subclavian and pulmonary arteries, in contemporary practice a modified version of the procedure, the mBTT shunt, is more commonly used.<ref name="mBTT" /><ref name=":0">{{Cite journal|last1=Kiran|first1=Usha|last2=Aggarwal|first2=Shivani|last3=Choudhary|first3=Arin|last4=Uma|first4=B.|last5=Kapoor|first5=Poonam Malhotra|date=July 2017|title=The Blalock and Taussig Shunt Revisited|journal=Annals of Cardiac Anaesthesia|volume=20|issue=3|pages=323–330|doi=10.4103/aca.ACA_80_17|issn=0974-5181|pmc=5535574|pmid=28701598 |doi-access=free }}</ref> In the modified Blalock–Thomas–Taussig shunt, a length of artificial tubing typically made from ] (]) is sewn between either the subclavian or the carotid artery and the corresponding side branch of the pulmonary artery.<ref name=":0" /> This modification removes the need to cut off blood supply and makes it easier to regulate the blood flow to the lungs. Some centers now use a shunt directly from the right ventricle to the pulmonary artery, a ]. This is done to avoid the reduced diastolic blood flow in the ] associated with the mBTT shunt.{{citation needed|date=June 2020}}


==History== ==History==
Line 34: Line 34:


<gallery> <gallery>
File:Blalock Taussig Shunt - Subclavian to Pulmonary.png|Blalock–Taussig Shunt – left subclavian artery to left pulmonary artery. File:Blalock Taussig Shunt - Subclavian to Pulmonary.png|Blalock–Thomas-Taussig Shunt – left subclavian artery to left pulmonary artery.
</gallery> </gallery>



Latest revision as of 06:01, 5 August 2024

Cardiac surgery procedure
This article includes a list of references, related reading, or external links, but its sources remain unclear because it lacks inline citations. Please help improve this article by introducing more precise citations. (August 2020) (Learn how and when to remove this message)
Medical intervention
Blalock–Thomas–Taussig shunt
Modified Blalock–Thomas–Taussig Shunt connecting right subclavian artery to pulmonary artery
Other namesBlalock–Taussig shunt, BTT shunt
SpecialtyCardiothoracic surgery
UsesPulmonary atresia, tetralogy of Fallot
ComplicationsChylothorax, phrenic nerve injury, pulmonary oedema, shunt stenosis, subclavian steal syndrome
ApproachThoracotomy or sternotomy
TypesClassical, modified
[edit on Wikidata]

The Blalock–Thomas–Taussig shunt (BTT shunt), previously known as the Blalock–Taussig Shunt (BT shunt), is a surgical procedure used to increase blood flow to the lungs in some forms of congenital heart disease such as pulmonary atresia and tetralogy of Fallot, which are common causes of blue baby syndrome. The procedure involves connecting a branch of the subclavian artery or carotid artery to the pulmonary artery. In modern practice, this procedure is temporarily used to direct blood flow to the lungs and relieve cyanosis while the infant is waiting for corrective or definitive surgery when their heart is larger. The BTT shunt is used in the first step of the three-stage palliation (the Norwood procedure).

Alternatives

Blalock–Thomas–Taussig shunt – A) original procedure – B) modified procedure

While the originally described Blalock–Thomas–Taussig shunt directly connected the subclavian and pulmonary arteries, in contemporary practice a modified version of the procedure, the mBTT shunt, is more commonly used. In the modified Blalock–Thomas–Taussig shunt, a length of artificial tubing typically made from PTFE (Gore-tex) is sewn between either the subclavian or the carotid artery and the corresponding side branch of the pulmonary artery. This modification removes the need to cut off blood supply and makes it easier to regulate the blood flow to the lungs. Some centers now use a shunt directly from the right ventricle to the pulmonary artery, a Sano shunt. This is done to avoid the reduced diastolic blood flow in the coronary circulation associated with the mBTT shunt.

History

The original procedure was named for Alfred Blalock, surgeon, Culloden, GA (1899–1964), Helen B. Taussig, cardiologist, Baltimore/Boston (1898–1986) and Vivien Thomas (1910–1985) who was at that time Blalock's laboratory assistant. They all helped to develop the procedure. Taussig, who treated hundreds of infants and children with this disorder, had observed that children with a cyanotic heart defect and a patent ductus arteriosus (PDA) lived longer than those without the PDA. It, therefore, seemed to her that a shunt that mimicked the function of a PDA might relieve the tetralogy patients' poor oxygenation. In 1943, having broached the possibility of a surgical solution to Robert Gross of Boston without success, Taussig approached Blalock and Thomas in their Hopkins laboratory in 1943. According to the account of the original consultation between the three provided in Vivien Thomas' 1985 autobiography Partners of the Heart, Taussig carefully described the anomaly of Tetralogy of Fallot, but made no suggestion about the specific surgical correction required, observing merely that it should be possible to get more blood to the lungs, "as a plumber changes pipes around." Although Taussig was not aware of it at that time, Blalock and Thomas had already experimented with such an anastomosis, one that Blalock had conceived years earlier for a different purpose but which had the unanticipated effect of re-routing blood to the lungs. The operation involved the joining of the subclavian artery to the pulmonary artery. After meeting with Taussig, the two men set about perfecting the operation in the animal lab, with Thomas performing the subclavian-to-pulmonary anastomosis alone in some 200 laboratory dogs, then adapting the instruments for the first human surgery from those used on the experimental animals and coaching Blalock through the first 100 operations on infants.

Thomas' autobiographical account, corroborated by the participants in the early tetralogy operations (Denton Cooley and the late William P. Longmire, Jr., intern and resident respectively during the surgery) has led to the recent conclusion that Thomas' contribution, both experimentally and clinically, was so critical that he should have received credit for the procedure along with Blalock and Taussig. However, because of the racial prejudices of the time, and the academic custom which generally precluded mention of non-degreed lab assistants (Thomas had no formal education beyond high school), he did not receive the honor of having the shunt named after him. The 2004 HBO television movie Something the Lord Made, based on Washingtonian writer Katie McCabe's 1989 article of the same name, was made about his role in the historic Blue Baby surgery, as was the 2003 public television documentary Partners of the Heart.

  • Blalock–Thomas-Taussig Shunt – left subclavian artery to left pulmonary artery. Blalock–Thomas-Taussig Shunt – left subclavian artery to left pulmonary artery.

References

  1. Blake, Kathleen; Yancy, Clyde W. (2022-04-01). "Change the Name of the Blalock–Taussig Shunt to Blalock–Thomas–Taussig Shunt". JAMA Surgery. 157 (4): 287–288. doi:10.1001/jamasurg.2021.5611. ISSN 2168-6254. PMID 34964811. S2CID 245538449.
  2. ^ Alahmadi, Mohamed H.; Bishop, Michael A. (2023-10-14). "Modified Blalock-Taussig-Thomas Shunt". StatPearls. PMID 37983362.
  3. ^ Yuan, Shi-Min; Shinfeld, Amihay; Raanani, Ehud (March 2009). "The Blalock–Taussig shunt". Journal of Cardiac Surgery. 24 (2): 101–108. doi:10.1111/j.1540-8191.2008.00758.x. ISSN 1540-8191. PMID 19040408.
  4. ^ Kiran, Usha; Aggarwal, Shivani; Choudhary, Arin; Uma, B.; Kapoor, Poonam Malhotra (July 2017). "The Blalock and Taussig Shunt Revisited". Annals of Cardiac Anaesthesia. 20 (3): 323–330. doi:10.4103/aca.ACA_80_17. ISSN 0974-5181. PMC 5535574. PMID 28701598.
  • Partners of the Heart: Vivien Thomas and His Work with Alfred Blalock, by Vivien T. Thomas (originally published as Pioneering Research in Surgical Shock and Cardiovascular Surgery: Vivien Thomas and His Work with Alfred Blalock), University of Pennsylvania Press, 1985. ISBN 0-8122-1634-2
Tests and procedures involving the heart
Surgery
Heart valves
and septa
production of septal defect in heart
enlargement of existing septal defect
Atrial septostomy
Balloon septostomy
creation of septal defect in heart
Blalock–Hanlon procedure
shunt from heart chamber to blood vessel
atrium to pulmonary artery
Fontan procedure
left ventricle to aorta
Rastelli procedure
right ventricle to pulmonary artery
Sano shunt
compound procedures
for transposition of the great vessels
Arterial switch operation
Mustard procedure
Senning procedure
for univentricular defect
Norwood procedure
Kawashima procedure
shunt from blood vessel to blood vessel
systemic circulation to pulmonary artery shunt
Blalock–Taussig shunt
SVC to the right PA
Glenn procedure
Cardiac vessels
CHD
Angioplasty
Bypass/Coronary artery bypass
MIDCAB
Off-pump CAB
TECAB
Coronary stent
Bare-metal stent
Drug-eluting stent
Obstacle removal
Endarterectomy
Atherectomy
Other
Pericardium
Pericardiocentesis
Pericardial window
Pericardiectomy
Myocardium
Cardiomyoplasty
Dor procedure
Septal myectomy
Ventricular reduction
Alcohol septal ablation
Conduction system
Maze procedure (Cox maze and minimaze)
Catheter ablation
Cryoablation
Radiofrequency ablation
Pacemaker insertion
S-ICD implantation
ICD implantation
Cardiac resynchronization therapy
Tests
Electrophysiology
Electrocardiography
Vectorcardiography
Holter monitor
Implantable loop recorder
Cardiac stress test
Bruce protocol
Electrophysiology study
Cardiac imaging
Angiocardiography
Echocardiography
TTE
TEE
Myocardial perfusion imaging
Cardiovascular MRI
Ventriculography
Radionuclide ventriculography
Cardiac catheterization/Coronary catheterization
Cardiac CT
Cardiac PET
sound
Phonocardiogram
Function tests
Pacing
Category
Vascular surgery
Vascular and
Endovascular surgery
Arterial disease
Venous disease
Arterial and venous access
Aortic aneurysm / dissection:
Other
Medical imaging
Angiography
Venography
Ultrasound
Other diagnostic
Categories: