Revision as of 21:11, 21 May 2008 editMarionTheLibrarian (talk | contribs)1,153 edits United States: Removed unsourced text.← Previous edit Latest revision as of 00:06, 26 February 2024 edit undoMaterialscientist (talk | contribs)Edit filter managers, Autopatrolled, Checkusers, Administrators1,994,280 editsm Reverted edits by 2600:1700:D8C0:35D0:6420:362C:73CC:6D13 (talk) (HG) (3.4.12)Tags: Huggle Rollback 
(422 intermediate revisions by more than 100 users not shown)
Line 1: Line 1:
{{short description|Measurement of bloodflow to the penis}}
The '''penile plethysmograph''' (PPG) is a controversial type of ] that measures changes in ] flow in the ] in response to audio and/or visual ]. It is typically used to determine the level of ] as the subject is exposed to sexually suggestive content, such as photos, movies or audio. It has been demonstrated by most studies to be the most accurate method of identifying which sexual offenders will go on to commit other sexual crimes against children,<ref>Hanson, R. K., & Bussière, M. T. (1998). Predicting relapse: A meta-analysis of sexual offender recidivism studies. ''Journal of Consulting and Clinical Psychology, 66,'' 348–362.</ref> although some clinicians disagree with using it at all.
{{Infobox interventions |
Name = Penile plethysmograph |
Image = |
Caption = |
ICD10 = |
ICD9 = {{ICD9proc|89.58}} |
MeshID = |
synonyms = Phallometry|
}}
'''Penile plethysmography''' ('''PPG''') or '''phallometry''' is a measurement of ] to the ], typically used as a proxy for measurement of ]. The most commonly reported methods of conducting penile plethysmography involves the measurement of the circumference of the penis with a mercury-in-rubber or electromechanical ], or the volume of the penis with an airtight cylinder and inflatable cuff at the base of the penis. ] nerve penile plethysmographs measure changes in response to inter-operative{{clarify|reason=What does the adjective "inter-operative" mean when modifying the noun phrase "electric stimulation"?|date=March 2021}} electric stimulation during surgery. The volumetric procedure was invented by ] and is considered to be particularly sensitive at low arousal levels. The easier to use circumferential measures are more widely used, however, and more common in studies using ] stimuli. A corresponding device in women is the ].<ref>Prause, Nicole, and Erick Janssen. "Blood flow: Vaginal photoplethysmography." Women's sexual function and dysfunction: Study, diagnosis, and treatment (2006): 359-367.</ref>


For sexual offenders it is typically used to determine the level of sexual arousal as the subject is exposed to sexually suggestive content, such as pictures, movies or audio, although some have argued that phallometry is not always appropriate for the evaluation of sexual preferences or treatment effects.<ref name="simon">{{cite journal |author1=Simon W. T. |author2=Schouten P. G. | year = 1992 | title = The plethysmograph reconsidered: Comments on Barker and Howell | journal = Bulletin of the American Academy of Psychiatry and the Law | volume = 20 | pages = 13–25 }}</ref> A 1998 large-scale meta-analytic review of the scientific reports demonstrated that phallometric response to stimuli depicting children, though only having a .32 ] with future sex offending (accounting for approximately 10% of the ]), had the highest accuracy among methods of identifying which sexual offenders will go on to commit new sexual crimes. (None of the methods were strong predictors with most accounting for far less than 10% of the variance).<ref name = Hanson1998>{{cite journal |author1=Hanson R. K. |author2=Bussière M. T. | year = 1998 | title = Predicting relapse: A meta-analysis of sexual offender recidivism studies | journal = Journal of Consulting and Clinical Psychology | volume = 66 | issue = 2| pages = 348–362 | doi=10.1037/0022-006x.66.2.348|pmid=9583338 }}</ref>
Significant suppliers of PPG machines include Behavioral Technology Inc. and Medical Monitoring Systems. The device is known to be used in ], ], ], ], ], ], ], ], ], ], and the ].


In ] ], the surgeon applies a mild electrical stimulation near the ] to verify their locations and avoid operative trauma. Damage to these difficult-to-see nerves can cause ] outcomes. At the surgery's conclusion, the electrical stimulation penile plethysmograph result is a ] which helps to manage the erectile function outcomes earlier than the many months required for recovery.<ref>{{cite journal |vauthors=Klotz L, Heaton J, Jewett M, etal |title=A randomized phase 3 study of intraoperative cavernosa nerve stimulation with penile tumescence monitoring to improve nerve sparing during radical prostatectomy |journal=J. Urol. |volume=164 |issue=5 |pages=1573–8 |date=November 2000 |pmid=11025707 |doi= 10.1016/S0022-5347(05)67031-0}}</ref>
==Types==


==Types==
{{more citations needed | section |date=July 2021}}
There are two types of penile plethysmograph: There are two types of penile plethysmograph:
* Volumetric air chamber
:When this is placed over the subject's penis, as ] increases, the air displaced is measured.
* Circumferential transducer
:This uses a mercury-in-rubber or indium/gallium-in-rubber ring or electromechanical ] and is placed around the shaft of the subject's penis to measure changes in circumference.


The circumferential type is more common,<ref>{{cite journal | author = Howes R. J. | year = 1995 | title = A survey of plethysmographic assessment in North America | journal = Sexual Abuse: A Journal of Research and Treatment | volume = 7 | pages = 9–24 | doi=10.1007/bf02254871| s2cid = 195271489 }}</ref> but the volumetric method is believed to be more accurate at low arousal levels.<ref>{{cite journal |vauthors=Kuban M, Barbaree HE, Blanchard R |title=A comparison of volume and circumference phallometry: response magnitude and method agreement |journal=Arch Sex Behav |volume=28 |issue=4 |pages=345–59 |date=August 1999 |pmid=10553495 |doi= 10.1023/A:1018700813140|s2cid=37559615 |url=http://www.kluweronline.com/art.pdf?issn=0004-0002&volume=28&page=345}}</ref>
* '''Volumetric air chamber''': When this is placed over the subject's penis, as ] increases, the air displaced is measured.
* '''Circumferential transducer''': This uses a mercury-in-rubber or indium/gallium-in-rubber ring ] and is placed around the shaft of the subject's penis to measure changes in circumference.


Significant suppliers of PPG machines include Behavioral Technology Inc. and Medical Monitoring Systems. The device is known to be used in ], ], ], ], ], ], ], ], ], ], and the ].
The circumferential type is more common,<ref>Howes, R. J. (1995). A survey of plethysmographic assessment in North America. ''Sexual Abuse: A Journal of Research and Treatment, 7,'' 9-24.</ref> but the volumetric method is more accurate.<ref>Kuban, M., Barbaree, H. E., & Blanchard, R. (1999). A comparison of volume and circumference phallometry: Response magnitude and method agreement. ''Archives of Sexual Behavior, 28,'' 345–359.</ref>


The surgical machine is supplied as CaverMap by Blue Torch Medical Technology, Inc.
==Development and uses==


A roughly equivalent procedure for women, ]y, measures blood through the walls of the ], which researchers claim increases during sexual arousal.
The original air device was developed by researcher ] in ] during the 1950s. He later wrote, "In the early fifies homosexual interaction was still an indictable offense in Czechoslovakia. I was of course opposed to this measure, but I still thought, as did my colleagues at the psychiatric university hospital in Prague where I was working, that homosexualiy was an experientially acquired neurosis" (p. 223)<ref>Freund, K. (1991). Reflections on the development of the phallometric method of assessing sexual preference. ''Annals of Sex Research, 4,'' 221–228.</ref> He then developed phallometry to replace psychoanalytic methods of assessment because "sychoanalysis had turned out to be a failure, virtually unusable as an instrument for individual diagnosis or research....When phallometry began to look promising as a test of erotic sex and age preferences, we started using it mainly as a test of pedophilia, that is determining who has an erotic preference for children over adults" (p. 223-224).


==Methodology==
Each different application of phallometry requires its own validation. Phallometry has been shown successfully to distinguish gay men from straight men. <ref>Adams, H. E., Mostinger, P., McAnulty, R. D., & Moore, A. L. (1992). Voluntary control of penile tumescence among homosexual and heterosexual subjects. ''Archives of Sexual Behavior, 21,'' 17–31.</ref><ref>Freund, K. (1963). A laboratory method of diagnosing predominance of homo- and hetero-erotic interest in the male. ''Behaviour Research and Therapy, 1,'' 85–93.</ref><ref>Freund, K. (1967). Diagnosing homo- or heterosexuality and erotic age preference by means of a psychophysiological test. ''Behavioral Research and Therapy, 5,'' 209–228.</ref> It has been shown to distinguish pedophilic men from nonpedophilic men.<ref>Blanchard, R., Klassen, P., Dickey, R., Kuban, M. E., & Blak, T. (2001). Sensitivity and specificity of the phallometric test for pedophilia in nonadmitting sex offenders. Psychological Assessment, 13, 118–126.</ref><ref>Freund, K., & Blanchard, R. (1989). Phallometric diagnosis of pedophilia. Journal of Consulting and Clinical Psychology, 57, 100–105.</ref><ref>Murphy, W. & Barbaree, H. E. (1994). Assessments of sexual offender by measures of erectile response: Psychometric properties and decision making. Brandon, VT: Safer Society Press.</ref> Phallometry can distinguish men with erotic interests in cross-dressing from non-cross-dressers.<ref>Buhrich, N., & McConaghy, N. (1977). The discrete syndromes of transvestism and transsexualism. Archives of Sexual Behavior, 6, 483–495.</ref><ref>Freund, K., Seto, M. C., & Kuban, M. (1996). Two types of fetishism. Behaviour Research and Therapy, 34, 687–694.</ref> There is some evidence that phallometry can distinguish groups of men with a ] involving rape from groups of men without it.<ref>Seto, M. C., & Kuban, M. (1996). Criterion-related validity of a phallometric test for paraphilic rape and sadism. Behaviour Research and Therapy, 34, 175–183.</ref>
Exact procedures can vary, but in one study a seventeen-year-old male sex offender was, at the start of each daily session, privately fitted with a ] mercury strain gauge attached to his penis and worn under trousers and underwear. The device had previously been calibrated with measurements from his penis in its flaccid state and at full erection as achieved through masturbation. This device was connected to a microprocessor, a battery pack, and a strain gauge amplifier, all of which were kept discreetly in a fanny pack. He was then driven daily to a college campus for multiple sessions to assess his sexual attraction to women and men, who were about 30–100 feet away from him. While remaining in a parked car, he was instructed to focus on either a specific woman or a specific man in the setting, imagine himself having sex with them, and allow himself to become sexually aroused if he was so inclined. The device then measured the percentage of full erection that he achieved. This was repeated over a period of 24 days, with the results showing a significantly greater level of attraction to women, especially when research staff were discreetly absent.<ref name="rea-experiment">{{cite journal |last1=Rea |first1=Jerry |last2=DeBriere |first2=Terry |last3=Butler |first3=Kasey |last4=Saunders |first4=Kathryn | year = 1998 | title = An Analysis of Four Sexual Offenders' Arousal in the Natural Environment Through the Use of a Portable Penile Plethysmograph | journal = ] | volume = 10 |issue=3 | pages = 239–255 |doi=10.1177/107906329801000307 |s2cid=145083086 }}</ref>


== United States == ==History==
The original volumetric was developed during the 1950s by ] in then-]. Freund later wrote, "In the early fifties homosexual interaction was still an indictable offense in Czechoslovakia. I was of course opposed to this measure, but I still thought, as did my colleagues at the psychiatric university hospital in Prague where I was working, that homosexuality was an experientially acquired neurosis". He then developed phallometry to replace ] methods of assessment because "sychoanalysis had turned out to be a failure, virtually unusable as an instrument for individual diagnosis or research....When phallometry began to look promising as a test of erotic sex and age preferences, we started using it mainly as a test of ], that is determining who has an erotic preference for children over adults".<ref>{{cite journal | author = Freund K | year = 1991 | title = Reflections on the development of the phallometric method of assessing sexual preference | journal = Annals of Sex Research | volume = 4 | issue = 3–4| pages = 221–228 | doi = 10.1007/BF00850054 | s2cid = 145609210 }}</ref>
According to Barker and Howell, penile plethysmography (PPG) cannot meet most legal thresholds as a valid or relevant diagnostic tool for the following reasons:


In post–World War II Czechoslovakia, Freund was assigned by the communist government the task of identifying among military conscripts men who were falsely declaring themselves to be gay to avoid the draft.<ref name = wilson2006>Wilson, R. J., & Mathon, H. F. (2006, fall). Remembering Kurt Freund (1914-1996). ''ATSA Forum.'' Beaverton, OR: Association for the Treatment of Sexual Abusers.</ref><ref>{{Cite web|url=https://skepdic.com/penilep.html|title=penile plethysmograph (PPG) - The Skeptic's Dictionary - Skepdic.com|website=skepdic.com}}</ref> "Freund (1957) developed the first device, which measured penile volume changes... to distinguish heterosexual and homosexual males for the Czechoslovakian army."<ref name="odonohue">W O'Donohue, E Letourneau. The psychometric properties of the penile tumescence assessment of child molesters. Journal of Psychopathology and Behavioral Assessment, 1992</ref> When he escaped Europe for Canada, Freund was able to pursue his research using phallometry for the assessment of sexual offenders.<ref name = wilson2006/> At that time, attempts to develop methods of changing homosexual men into heterosexual men were being made by many sexologists, including ],<ref>{{cite journal |author=Bancroft J |title=Aversion therapy of homosexuality. A pilot study of 10 cases |journal=Br J Psychiatry |volume=115 |issue=529 |pages=1417–31 |date=December 1969 |pmid=5358532 |doi=10.1192/bjp.115.529.1417|s2cid=9427323 }}</ref> ],<ref>{{cite journal | author = Ellis A | year = 1956 | title = The effectiveness of psychotherapy with individuals who have severe homosexual problems | journal = Journal of Consulting Psychology | volume = 20 | issue = 3| pages = 191–195 | doi=10.1037/h0044762| pmid = 13357645 }}</ref> and ] of the ] Institute.<ref>{{cite journal |vauthors=Schwartz MF, Masters WH |title=The Masters and Johnson treatment program for dissatisfied homosexual men |journal=Am J Psychiatry |volume=141 |issue=2 |pages=173–81 |date=February 1984 |pmid=6691475 |doi= 10.1176/ajp.141.2.173}}</ref> Because phallometry showed that such methods were failures, Freund was among the first sexologists to declare that such attempts were unethical.<ref name = wilson2006/><ref>{{Cite web |url=http://archive.southcoasttoday.com/daily/10-96/10-29-96/c06wn888.htm |title=Archived copy |access-date=2008-05-30 |archive-date=2010-01-02 |archive-url=https://web.archive.org/web/20100102065821/http://archive.southcoasttoday.com/daily/10-96/10-29-96/c06wn888.htm |url-status=dead }}</ref> Based primarily on Freund's studies, decriminalization of homosexuality took place in Czechoslovakia in 1961. (See also ].)
*No standardization
*Test results are not sufficiently accurate
*Results are subject to faking and voluntary control by test subjects
*High incidence of false negatives and false positives
*Results are open to interpretation <ref name="barker">Barker and Howell, The Plethysmograph: A Review of Recent Literature, 20 Bull. Am. Acad. of Psychiatry and Law 13 (1992)</ref>


==Reliability and validity==
In ''State of North Carolina v. Spencer''<ref name="spencer">North Carolina v. Spencer, 459 S.E.2d 812, 815 (N.C. Ct. App. 1995),</ref>, the court reviewed the literature and case law and concluded that penile plethysmography was scientifically unreliable: "Despite the sophistication of the current equipment technology, a question remains whether the information emitted is a valid and reliable means of assessing sexual preference."
In 1994, the '']'' (Fourth Edition) of the ] stated that penile plethysmography has been used in research settings to assess various paraphilias by measuring an individual's sexual arousal in response to visual and auditory stimuli. The reliability and validity of this procedure in clinical assessment have not been well established, and clinical experience suggests that subjects can simulate response by manipulating mental images."<ref name="dsmiv">DSM-IV, p. 524.</ref> In contrast, a 2017 recent meta-analysis provides support for the validity of phallometric testing as a measure of sexual interests in children across 37 samples and 6,785 individuals.<ref name=":0">{{Cite journal|last1=McPhail|first1=Ian V.|last2=Hermann|first2=Chantal A.|last3=Fernane|first3=Stephanie|last4=Fernandez|first4=Yolanda M.|last5=Nunes|first5=Kevin L.|last6=Cantor|first6=James M.|title=Validity in Phallometric Testing for Sexual Interests in Children: A Meta-Analytic Review|journal=Assessment|volume=26|issue=3|pages=535–551|language=en|doi=10.1177/1073191117706139|pmid=28454493|year=2017|s2cid=35657151}}</ref>


In 1998, Hanson and Bussière published a comprehensive meta-analysis of 61 scientific reports on the prediction of sexual offenses spanning more than 40,000 individual cases. They ascertained that of all the methods attempted and reported, penile phethysmographic responses to imagery depicting ] was the single most accurate predictor of sexual re-offense across 7 studies reporting data from phallometric testing.<ref name = Hanson1998/> Another meta-analysis in 2005 of 13 studies and 2,180 individual cases repeated the finding that phallometric responses to children was a strong predictor of sexual re-offense.<ref>{{cite journal |author1=Hanson R. K. |author2=Morton-Bourgon K. E. | year = 2005 | title = The characteristics of persistent sexual offenders: A meta-analysis of recidivism studies | journal = Journal of Consulting and Clinical Psychology | volume = 73 | issue = 6| pages = 1154–1163 | doi=10.1037/0022-006x.73.6.1154 | pmid=16392988| hdl = 10983/26131 |s2cid=14984239 | hdl-access = free }}</ref>
The penile plethysmograph is not intended to be used as a guilt or innocence tool, but rather as a supplemental device to add to a complete psychosexual evaluation. Some of the criticisms of PPG articulated by various criminal courts relate to the blatant misuse of PPG as a tool to determine whether a defendant committed a particular crime.


A 2017 meta-analysis that included 16 samples and 2,709 sexual offenders replicated and extended the previous findings that phallometric responding to children is a predictor of sexual re-offence.<ref name=":0" /> This meta-analysis extended previous meta-analytic research by showing phallometric responding to both male and female pedophilic and ] stimuli predict sexual re-offence. Further, this meta-analysis showed that phallometric testing predicts sexual re-offence in distinct subgroups of sexual offenders against children.
In recent years, a substantial amount of research data has been gathered and reviewed, and significant steps have been taken toward standardization.


===Critique of methodological problems===
The device has also been used in many states when evaluating convicted ]. The ] trial of ] player ] in ] brought this device and its use to public attention before the case was dropped in ], because Colorado law would have required evaluation with this device following conviction.
There are criticisms of the methodology used to determine the reliability and specificity of penile plethysmography. One such criticism is that while penile plethysmography is said to be important for being more objective than a test subject's subjective reports on sexual arousal, the argument for penile plethysmography being a more reliable gauge of sexual arousal than vaginal plethysmography is still that there is a higher correspondence on average between what the test subjects report and what the instruments observe in male subjects than in female subjects. There is a criticism of this discrepancy for lacking consistency in the standards of whether or not subjective reports are useful. There is also criticism regarding the possibility of sampling bias being greater in male subjects of penile plethysmography than in female subjects of vaginal plethysmography, males being generally more aware of their physical sexual responses than females in most cultures may cause the male volunteers to be almost exclusively individuals who have category specific erections due to those with nonspecific erections fearing erection in taboo contexts and therefore not signing up for the studies. This effect may explain apparent male specificity as a result of methodological bias. The difference between tests of volunteers and tests of convicted or suspected sex offenders in penile plethysmography results may be caused by the sex offender group often effectively lacking the choice not to volunteer, without difference in erection patterns from the average population. One criticism of reoffending studies is that cultural attitudes that assume that men are sexually attracted to what they phallometrically respond to may cause men with no actual sexual interest in children to identify as pedophiles due to knowing that they phallometrically respond to them, making them more likely to be convicted again.<ref>Science and Pseudoscience in Clinical Psychology, Scott O. Lilienfeld, Steven Jay Lynn, Jeffrey M. Lohr 2015</ref><ref>At the Fringes of Science, 1998, Michael W. Friedlander</ref>


==Utility==
During the priest sexual abuse scandal, the reliability of the test was questioned by some diocesan officials in Philadelphia, PA. Later, these officials chose to seek therapy at an institution where the plethysmograph was not used. This, even though the officials were made aware of the fact that the test was used by most experts and was believed to be of value in diagnosing sexual disorders. Later, a Grand Jury found that the Archdiocese of Philadelphia's decision to do so "had the effect of diminishing the validity of the evaluations and the liklihood that a priest would be diagnosed as a pedophile or ephebophile."<ref>''Court of Common Pleas, First Judicial District of PA'', County Investigating Grand Jury, 9-17-2003

=== Erectile dysfunction ===
The penile plethysmograph has value in screening organic versus psychogenic ] in ] ] centres.<ref>{{Cite web|url=https://www.freepatentsonline.com/5377691.html|title=Plural-characteristic-measuring radial erectometer}}</ref> Lack of sexual response during ] may indicate that further evaluation by a ] is required.<ref name="marshall">{{cite journal |vauthors=Marshall P, Surridge D, Delva N |title=The role of nocturnal penile tumescence in differentiating between organic and psychogenic impotence: the first stage of validation |journal=Arch Sex Behav |volume=10 |issue=1 |pages=1–10 |date=February 1981 |pmid=7212992 |doi= 10.1007/BF01542669|s2cid=9912262 }}</ref>

When applied during ], electrical stimulation penile plethysmograph is an erectile dysfunction prognostic. The patient is provided with objective information on his specific outcome which aids in planning for further erectile function therapies.<ref>{{cite journal |author=Klotz L |title=Cavernosal nerve mapping: current data and applications |journal=BJU Int. |volume=93 |issue=1 |pages=9–13 |date=January 2004 |pmid=14678359 |doi= 10.1111/j.1464-410X.2004.04546.x|doi-access=free }}</ref>

===Pedophilia, hebephilia, pedohebephilia, and ephebophilia===
Studies examining the efficiency of using penile plethysmograph to distinguish ] men from non-pedophilic men, including ], show that a majority can be correctly assigned to the proper category.<ref name="pmid11281033">{{cite journal |vauthors=Blanchard R, Klassen P, Dickey R, Kuban ME, Blak T |title=Sensitivity and specificity of the phallometric test for pedophilia in nonadmitting sex offenders |journal=Psychol Assess |volume=13 |issue=1 |pages=118–26 |date=March 2001 |pmid=11281033 |doi= 10.1037/1040-3590.13.1.118|url=http://content.apa.org/journals/pas/13/1/118}}</ref><ref name="57-1-100">{{cite journal |vauthors=Freund K, Blanchard R |title=Phallometric diagnosis of pedophilia |journal=J Consult Clin Psychol |volume=57 |issue=1 |pages=100–5 |date=February 1989 |pmid=2925958 |doi= 10.1037/0022-006X.57.1.100|url=http://content.apa.org/journals/ccp/57/1/100}}</ref><ref>Murphy, W. & Barbaree, H. E. (1994). Assessments of sexual offender by measures of erectile response: Psychometric properties and decision making. Brandon, VT: Safer Society Press.</ref> ] of a phallometric test is defined as the accuracy of the test to identify pedophilic (or hebephilic) individuals as having these sexual interests. ] of these tests is defined as the accuracy of the test to identify non-pedophilic (or non-hebephilic) individuals as such. Meta-analytic research has shown that sexual offenders against children show greater responding on phallometric tests for pedophilia and hebephilia than controls.<ref name=":0" />

==== Volumetric penile plethysmography ====
In one study, 21% of the subjects were excluded for various reasons, including "the subject's erotic age-preference was uncertain and his phallometrically diagnosed sex-preference was the same as his verbal claim" and attempts to influence the outcome of the test.<ref name="57-1-100"/> This study found the sensitivity for identifying ] in sexual offenders against children admitting to this interest to be 100%. In addition, the sensitivity for this phallometric test in partially admitting sexual offenders against children was found to be 77% and for denying sexual offenders against children to be 58%. The specificity of this volumetric phallometric test for pedohebephilia was estimated to be 95%.

Further studies by Freund have estimated the sensitivity of a volumetric test for pedohebephilia to be 35% for sexual offenders against children with a single female victim, 70% for those with two or more female victims, 77% for those offenders with one male victim, and 84% for those with two or more male victims.<ref>{{cite journal|last1=Freund|first1=K.|last2=Watson|first2=R. J.|title=Assessment of the sensitivity and specificity of a phallometric test: An update of phallometric diagnosis of pedophilia|journal=Psychological Assessment|date=1991|volume=3|issue=2|pages=254–260|doi=10.1037/1040-3590.3.2.254}}</ref> In this study, the specificity of the test was estimated to be 81% in community males and 97% in sexual offenders against adults. In a similar study, the sensitivity of a volumetric test for pedophilia to be 62% for sexual offenders against children with a single female victim, 90% for those with two or more female victims, 76% for those offenders with one male victim, and 95% for those with two or more male victims.<ref>{{cite journal|last1=Freund|first1=K.|last2=Watson|first2=R. J.|title=The proportions of heterosexual and homosexual pedophiles among sex offenders against children: An exploratory study|journal=Journal of Sex & Marital Therapy|date=1992|volume=18|issue=1|pages=34–43|doi=10.1080/00926239208404356|pmid=1556756}}</ref>

In a separate study, sensitivity of the method to distinguish between pedohebephilic men from non-pedohebephilic men was estimated between 29% and 61% depending on subgroup.<ref name="pmid11281033"/> Specifically, sensitivity was estimated to be 61% for sexual offenders against children with three or more victims and 34% in incest offenders. The specificity of the test using a sample of sexual offenders against adults was 96% and the ] for the test was estimated to be .86. Further research by this group found the specificity of this test to be 83% in a sample of non-offenders.<ref>{{cite journal|last1=Blanchard|first1=R.|last2=Kuban|first2=M. E.|last3=Blak|first3=T.|last4=Cantor|first4=J. M.|last5=Klassen|first5=P|last6=Dickey|first6=R|title=Phallometric comparison of pedophilic interest in nonadmitting sexual offenders against stepdaughters, biological daughters, other biologically related girls, and unrelated girls|journal=Sexual Abuse: A Journal of Research and Treatment|date=2006|volume=18|issue=1|pages=1–14|doi=10.1177/107906320601800101|pmid=16598663|citeseerx=10.1.1.1016.1030|s2cid=220355661}}</ref> More recent research has found volumetric phallometry to have a sensitivity of 72% for pedophilia, 70% for hebephilia, and 75% for pedohebephilia and a specificity of 95%, 91%, and 91% for these paraphilias, respectively.<ref>{{cite journal|last1=Cantor|first1=James|last2=McPhail|first2=Ian|title=Sensitivity and specificity of the phallometric test for hebephilia|journal=Journal of Sexual Medicine|date=2015|volume=Online first|issue=9|doi=10.1111/jsm.12970|pmid=26272778|pages=1940–1950}}</ref>

==== Circumferential penile plethysmography ====
Other studies have examined the sensitivity and specificity of circumferential phallometry to identify different sexual interests in children. Sensitivity for a circumferential phallometric test for pedophilia has been estimated to be 63% in sexual offenders against children,<ref name="abel et al">{{cite journal|last1=Abel|first1=G. G.|last2=Huffman|first2=J.|last3=Warberg|first3=B.|last4=Holland|first4=C. L.|title=Visual reaction time and plethysmography as measures of sexual interest in child molesters|journal=Sexual Abuse: A Journal of Research and Treatment|date=1998|volume=10|issue=2|doi=10.1177/107906329801000202|pages=81–95|s2cid=220352804}}</ref> 65% in extrafamilial offenders against children and 68.4% in incest offenders.<ref>{{cite journal|last1=Barsetti|first1=I.|last2=Earls|first2=C. M.|last3=Lalumiere|first3=M. L.|last4=Belanger|first4=N.|title=The differentiation of intrafamilial and extrafamilial heterosexual child molesters|journal=Journal of Interpersonal Violence|date=1998|volume=13|issue=2|doi=10.1177/088626098013002007|pages=275–286|s2cid=144592544}}</ref> Additional research has found different circumferential phallometric tests to have a sensitivity of 93%,<ref name="Chaplin et al 1995">{{cite journal|last1=Chaplin|first1=T. C|last2=Rice|first2=M. E.|last3=Harris|first3=G. T.|title=Salient victim suffering and the sexual responses of child molesters|journal=Journal of Consulting and Clinical Psychology|date=1995|volume=63|issue=2|pages=249–255|doi=10.1037/0022-006x.63.2.249|pmid=7751485}}</ref> 96%,<ref name="Harris et al 1996">{{cite journal|last1=Harris|first1=G. T.|last2=Rice|first2=M. E.|last3=Quinsey|first3=V. L.|last4=Chaplin|first4=T. C.|title=Viewing time as a measure of sexual interest among child molesters and normal heterosexual men|journal=Behaviour Research and Therapy|date=1996|volume=34|issue=4|pages=389–394|doi=10.1016/0005-7967(95)00070-4|pmid=8871372}}</ref> 35%,<ref name="Looman">{{cite journal|last1=Looman|first1=J.|last2=Marshall|first2=W. L.|title=Phallometric assessment designed to detect arousal to children: The responses of rapists and child molesters|journal=Sexual Abuse: A Journal of Research and Treatment|date=2001|volume=13|issue=1|pages=3–13|doi=10.1177/107906320101300102|s2cid=144505915}}</ref> 78%,<ref name="Muller">{{cite journal|last1=Muller|first1=K.|last2=Curry|first2=S.|last3=Ranger|first3=R.|last4=Briken|first4=P.|last5=Bradford|first5=J.|last6=Federoff|first6=J. P.|title=Changes in sexual arousal as measured by penile plethysmography in men with pedophilic sexual interests|journal=Journal of Sexual Medicine|date=2014|volume=11|issue=5|pages=1221–1229|doi=10.1111/jsm.12488|pmid=24636071}}</ref> and 50%<ref name="Wormith">{{cite journal|last1=Wormith|first1=S|title=Assessing deviant sexual arousal: Physiological and cognitive aspects|journal=Advances in Behaviour Research and Therapy|date=1986|volume=8|issue=3|pages=101–137|doi=10.1016/0146-6402(86)90001-9}}</ref> in sexual offenders against children. In incest offenders, the sensitivity of circumferential phallometric tests has been estimated as 19% and 60% in extrafamilial offenders against children.<ref name="Marshall">{{cite journal|last1=Marshall|first1=W. L.|last2=Barbaree|first2=H. E.|last3=Christophe|first3=D.|title=Sexual offenders against female children: Sexual preferences for age of victims and type of behaviour|journal=Canadian Journal of Behavioural Science|date=1986|volume=18|issue=4|pages=424–439|doi=10.1037/h0079966}}</ref> In terms of specificity of these tests for pedophilia, research has estimated the specificity as 92%,<ref name="Harris et al 1996" /> 82%,<ref name="Marshall" /> 76%,<ref name="Muller" /> and 92%<ref name="Wormith" /> in samples of community males and 80%<ref name="Looman" /> and 92%<ref name="Wormith" /> in sexual offenders against adults.

A single study has examined the accuracy of a circumferential phallometric test for hebephilia.<ref name="Marshall" /> This study found the sensitivity of the hebephilia test to be 70% in extrafamilial offenders against children and 52% in incest offenders. In addition, the specificity for this phallometric test was 68% in a sample of community males.

Other studies have found different phallometric tests for pedohebephilia to have a sensitivity of 75% in incest offenders, 67% in extrafamilial offenders against children,<ref>{{cite journal|last1=Fernandez|first1=Yolanda|title=Phallometric testing with sexual offenders against female and male victims: An examination of reliability and validity issues|journal=Unpublished Doctoral Dissertation|date=2001}}</ref> and 64%,<ref>{{cite journal|last1=Goyette|first1=M.|title=Évaluation des intérêts sexuels auprès d'agresseurs sexuels d'enfants par la vidéo-oculographie et la présentation de stimuli générés par ordinateur|journal=Unpublished Doctoral Dissertation|date=2012}}</ref> 64%,<ref>{{cite journal|last1=Gray|first1=S. R.|last2=Plaud|first2=J. J.|title=A comparison of the Abel Assessment for Sexual Interests and penile plethysmography in an outpatient sample of sexual offenders|journal=Journal of Sexual Offender Civil Commitment: Science and the Law|date=2005|volume=1|pages=1–10}}</ref> 44%,<ref name="Looman" /> and 53%,<ref>{{cite journal|last1=Malcolm|first1=P. B.|last2=Andrews|first2=D. A.|last3=Quinsey|first3=V. L.|title=Discriminant and predictive validity of phallometrically measured sexual age and gender preference|journal=Journal of Interpersonal Violence|date=1993|volume=8|issue=4|pages=486–501|doi=10.1177/088626093008004004|s2cid=144688361}}</ref> in sexual offenders against children.

In addition, Abel and colleagues found ] stimuli to have a sensitivity of 50%.<ref name="abel et al" />

Another study examined the possibility that juvenile sex offenders might be able to suppress arousal deemed deviant. Of the juveniles who exhibited sexual arousal, categorization was made into two age appropriate categories—Adult and Peer responders—and three age inappropriate categories—Child, Child/Adult, and Nondiscriminating responders—based on whether they had the greatest sexual arousal in response to adult female, peer female, or younger child female stimuli. Sexual arousal in response to older adult women or peers was deemed age appropriate; sexual arousal in response to significantly younger females was deemed inappropriate. Many of the juveniles who denied responsibility for their offenses showed no sexual arousal at all—however about one-third still showed age inappropriate arousal despite denying responsibility for their offenses.<ref name="23-1-87">{{cite journal |author1=Becker J.V. |author2=Kaplan M |author3=Tenke C |title=The Relationship of Abuse History, Denial and Erectile Response Profiles of Adolescent Sexual Perpetrators |journal=Behavior Therapy |volume=23 |issue=1 |pages=87–97 |date=Winter 1992 |doi=10.1016/s0005-7894(05)80310-7|doi-access=free }}</ref>

===Biastophilia===
There is some evidence that phallometry can distinguish groups of men with ] (a ] involving ]) from groups of men without it.<ref>{{cite journal |author1=Seto M. C. |author2=Kuban M. | year = 1996 | title = Criterion-related validity of a phallometric test for paraphilic rape and sadism | journal = Behaviour Research and Therapy | volume = 34 | issue = 2| pages = 175–183 | doi=10.1016/0005-7967(95)00056-9|pmid=8741725 }}</ref>

==Legal admissibility==
In general, phallometric test results are employed as part of the sentencing and rehabilitation phase of forensic systems, but ''not'' for determining whether a specific defendant is guilty of any specific offense against any specific person.

=== United States ===

====Use as trial evidence====
In the ], a scientific technique could not be used as evidence in court unless the technique was "generally accepted" as reliable in the relevant scientific community. This was known as the ], adopted in 1923. In 1993, the doctrine was rejected by the ] in favor of a more comprehensive "reliable foundation" test in '']''. In the ], the "generally accepted" test was no longer determinative. Several other factors could now be considered, including whether the technique had been published and peer-reviewed. Myers notes, "Courts that have considered penile plethysmography generally rule that the technique is not sufficiently reliable for use in court."<ref name="myers">Myers JEB (2005). ''Myers on Evidence in Child, Domestic, and Elder Abuse Cases.'' Aspen Publishers Online {{ISBN|0-7355-5668-7}}</ref>

In ''United States v. Powers'' the court excluded the penile plethysmograph test because it failed to qualify under Daubert's scientific validity prong for two reasons: the scientific literature does not regard the test as a valid diagnostic tool, and "a vast majority of incest offenders who do not admit their guilt, such as Powers, show a normal reaction to the test. The Government argues that such ]s render the test unreliable."<ref name="powers">''United States v. Powers'', 59 F.3d 1460 (4th Cir. 1995)</ref>

According to Barker and Howell, penile plethysmography (PPG) does not meet the legal threshold for the guilt phase for the following reasons:<ref name="barker">{{cite journal | author = Barker James G., Howell Robert J. | year = 1992 | title = The Plethysmograph: A Review of Recent Literature | journal = Journal of the American Academy of Psychiatry and the Law | volume = 20 | issue = 1| pages = 13–25 | pmid = 1576372 }}</ref>
* No standardization
* Test results are not sufficiently accurate
* Results are subject to faking and voluntary control by test subjects
* High incidence of false negatives and false positives
* Results are open to interpretation

They concluded, "Until a way can be devised to detect and/or control false negatives and false positives, the validity of the test data will be questionable."<ref name="barker"/> Responding to Barker and Howell, Simon and Schouten noted, "Our own analysis suggests that the standardization and faking issues, as well as other problems not addressed in the Barker and Howell paper, warrant much more guarded conclusions about the use of the plethysmograph in legal and clinical settings."<ref name="simon"/> Prentky noted "the increased likelihood in forensic settings that dissimulation may compromise the validity of the assessment."<ref name="prentky">Prentky RA, Knight RA, Lee AFS (1997) Risk factors associated with recidivism among extrafamilial child molesters. ''Journal of Consulting and Clinical Psychology.''</ref> Hall and Crowther noted penile plethysmography "may be even more problematic than other in assessing susceptibility of the test to faking."<ref name="hall">Hall GCN, Crowther JH (1991). Psychologists' involvement in cases of child maltreatment: additional limits of assessment methods. '']'' Jan Vol 46(1) 79-80</ref>

In ''State of North Carolina v. Spencer'',<ref name="spencer">North Carolina v. Spencer, 459 S.E.2d 812, 815 (N.C. Ct. App. 1995),</ref> the court reviewed the literature and case law and concluded that penile plethysmography was scientifically unreliable: "Despite the sophistication of the current equipment technology, a question remains whether the information emitted is a valid and reliable means of assessing sexual preference."

More recently, a substantial amount of research data has been gathered and reviewed, and significant steps have been taken toward standardization.{{Citation needed|date=June 2008}} According to researcher Gilles Launay, "he validity of the technique for research and clinical assessment is now established;"<ref>{{Cite journal | doi = 10.1002/cbm.317 | last1 = Launay | first1 = G. | year = 1999 | title = The phallometric assessment of sex offenders: an update | journal = Criminal Behaviour and Mental Health | volume = 9 | issue = 3| pages = 254–274 }}</ref> it is only the use in guilt-determination proceedings that is inappropriate.{{Citation needed|date=June 2008}} Fedoroff and Moran called it an "experimental procedure" and noted, "Virtually every expert who has written about phallometry has cautioned that it is insufficiently sensitive or specific to be used to determine the guilt or innocence of a person accused of a sex crime."<ref name="fedoroff">{{Cite journal | last1 = Fedoroff | first1 = JP | last2 = Moran | first2 = B | year = 1997 | title = Myths and Misconceptions about Sex Offenders | journal = The Canadian Journal of Human Sexuality | volume = 6 | page = 1997 }}</ref>

====Post-conviction use====
Phallometry is widely considered appropriate for treatment and supervision of convicted ]: "Courts have permitted plethysmographic testing for monitoring compliance by convicted sex offenders with the conditions of their community placement as part of crime-related treatment for sexual deviancy."<ref>Sachsenmaier, S. J., & Peters, J. M. (2002). Sexual offender risk assessment methods and admissibility as expert witness evidence. In J. M. Peters (Ed.), ''Assessment and management of sex offenders: What prosecutors need to know.'' Washington, DC: United States Department of Justice, Child Exploitation and Obscenity Section</ref> Its use for the treatment and management of sexual offenders is recommended by the ].<ref>Association for the Treatment of Sexual Abusers. (2004). ''ATSA Practice Standards and Guidelines for the evaluation, treatment and management of adult male sexual abusers.'' Beaverton, OR: Author.</ref> Becker notes it "should never be used exclusively in forensic decision making."<ref name="becker">Becker J.V., Murphy WD (1998). What we know and do not know about assessing and treating sex offenders. ''Psychology, Public Policy, and Law.'' Volume:4 Issue:1/2 Dated:March/June 1998 Pages:116 to 137</ref> The ] in ] brought this device and its use to public attention before the case was dropped in 2004, because Colorado law would have required evaluation with this device following conviction.<ref>Mark Shaw for USATODAY- </ref> The ] recently addressed the procedures required before a ] program could include penile plethysmograph testing.<ref name="usvweber">''United States v. Weber'', 2006 U.S. App. LEXIS 15111 (9th Cir. 2006).</ref> The device is routinely used at civil commitment facilities, but "some clinicians and offenders say it is easy, particularly in a laboratory, to stifle arousal and thus cheat on a plethysmograph test."<ref name="goodnough">Goodnough A, Davey M (March 6, 2007). '']''</ref> This has been reported to occur in 16% of cases.<ref name="pmid11281033"/>

During the ], the reliability of the test was questioned by some officials in the ]. Later, these officials chose to seek therapy at an institution where the plethysmograph was not used.<ref>''Court of Common Pleas, First Judicial District of PA'', County Investigating Grand Jury, 9-17-2003
</ref> </ref>


=== Canada ===
The Ninth Circuit Court of Appeals recently addressed the procedures required before a supervised release program could include penile plethysmograph testing. <ref name="usvweber">''United States v. Weber'', 2006 U.S. App. LEXIS 15111 (9th Cir. 2006).</ref>
{{tone|date=November 2023}}
Courts in ] came to a similar conclusion as those in the United States. The ] adopted the ] in ''R. v . J.-L.J.'' 2 S.C.R. 600, which upheld a lower court's decision to exclude testimony by a psychiatrist who had administered several tests on the accused, including a penile plethysmograph:


{{blockquote|A level of reliability that is quite useful in therapy because it yields some information about a course of treatment is not necessarily sufficiently reliable to be used in a court of law to identify or exclude the accused as a potential perpetrator of an offence. In fact, penile plethysmography has received a mixed reception in Quebec courts: ''Protection de la jeunesse'' – 539, R.J.Q. 1144; ''R. c. Blondin'', Q.J. No. 3605 (QL) (S.C.); L. Morin and C. Boisclair in "La preuve d'abus sexuel: allégations, déclarations et l'évaluation d'expert" (1992), 23 R.D.U.S. 27. Efforts to use penile plethysmography in the United States as proof of disposition have largely been rejected: ''People v. John W.'', 185 Cal.App.3d 801 (1986); ''Gentry v. State'', 443 S.E.2d 667 (Ga. Ct. App. 1994); ''United States v. Powers'', 59 F.3d 1460 (4th Cir. 1995); ''State v. Spencer'', 459 S.E.2d 812 (N.C. App. 1995); J. E. B. Myers et al., "Expert Testimony in Child Sexual Abuse Litigation" (1989), 68 ''Neb. L. Rev''. 1, at pp. 134-35; J. G. Barker and R. J. Howell, "The Plethysmograph: A Review of Recent Literature" (1992), 20 ''Bull. Am. Acad. of Psychiatry & L.'' 13.|<ref name="2SCR600">'' {{webarchive|url=https://web.archive.org/web/20081002000446/http://csc.lexum.umontreal.ca/en/2000/2000scc51/2000scc51.pdf |date=2008-10-02 }}'', 2 S.C.R. 600</ref>}}
== Canada ==


As of 2010, all youth in sex offender treatment programs administered by the Youth Forensic Psychiatric Service of ] were offered a voluntary penile plethysmograph test to predict whether they can properly control their deviant arousal, or whether they will require medication or other forms of treatment. According to sceptics, however, the test does not reliably predict recurrent violations.<ref> {{webarchive|url=https://archive.today/20120711073409/http://fullcomment.nationalpost.com/2010/07/29/adrian-macnair-b-c-government-rethinks-penis-arousal-tests/ |date=July 11, 2012 }}</ref>
Courts in Canada came to a similar conclusion as the United States. While the Daubert decision was greeted with harsh criticism from those who feared a flood of "]" in courtrooms, the Supreme Court of Canada adopted the Daubert doctrine in ''R. v. J. (J.L.)'' 2 S.C.R. 600 with very little fanfare. Interestingly, this statement by the court was contained in a decision which upheld a lower court's decision to exclude testimony by a psychiatrist who had administered several tests on the accused, including a penile plethysmograph.


===Ethics and legality of use===
After developing the device in Czechoslovakia, developer Kurt Freund fled to ] in the wake of the ]. Freund then began using the device at the ] in ], where much of the research and published data using the device originated.
] writes, "More objectionable than the questionable scientific validity of the device, however, are the moral and legal questions its use raises."<ref name="todd2003">Carroll, Robert Todd (2003). Penile plethysmograph (PPG). ''The skeptic's dictionary: a collection of strange beliefs, amusing deceptions, and dangerous delusions,'' pp. 278-281. John Wiley and Sons, {{ISBN|978-0-471-27242-7}}</ref> Carroll and others cite the legality of the depictions of minors, as well as the constitutionality of requiring PPG for admission to jobs or the military, or in custody cases. In ''Harrington v. Almy'' the ] found that a PPG ordered to be administered by ] as a precondition of employment was a violation of plaintiff's rights under the ].<ref name="harrison">''Harrington v. Almy'', 977 F.2d 37 (1st Cir.1992)</ref><ref name="ford1993">Ford, Royal (June 19, 1993). Maine officer who refused sex response test wins suit. '']''</ref> In a 2009 report led by Robert Clift on use of the device on adolescent offenders,<ref name="clift2009">{{Cite journal | doi = 10.1177/1079063209338491 | last1 = Clift | first1 = JRW | last2 = Rajlic | first2 = G | last3 = Gretton | first3 = H | year = 2009 | title = Discriminative and Predictive Validity of the Penile Plethysmograph in Adolescent Sex Offenders | journal = Sexual Abuse | volume = 21 | issue = 3| pages = 335–362 | pmid = 19587382 | s2cid = 7328366 }}</ref> the authors acknowledge in their conclusions that PPG tests "are problematic ethically and should be used only after therapists have carefully weighed the benefits versus the negatives."<ref name="bula2010">Bula, Frances (July 27, 2010). '']''</ref> The Minister of Children and Family Development closed the program examined in Clift's report in 2010 following complaints by civil rights groups.<ref name="cbc2010">Staff report (August 8, 2010). '']''</ref><ref name="ctv2010">Wintonyk, Darcy (July 29, 2010). '']''</ref> The principal manufacturer of the device stopped making them in the 1990s.<ref name="hyde1997">Hyde, Alan (1997). The legal penis. ''Bodies of Law,'' pp. 173 ff. Princeton University Press, {{ISBN|978-0-691-01228-5}}</ref>


The EU's leading human rights agency, the Fundamental Rights Agency, has criticised the use of phallometric tests by the Czech Republic to determine whether asylum seekers presenting themselves as homosexual were in fact gay. According to the Agency, the Czech Republic was in 2010 the only EU country to employ a sexual arousal test, which the Agency said could violate the ].<ref>{{Cite news|url=https://www.bbc.com/news/world-europe-11954499|title=Czech gay asylum 'phallometric test' criticised by EU|work=BBC News |date=December 8, 2010}}</ref> In 2011 the ] issued a statement calling the Czech practice illegal, saying "The practice of phallometric tests constitutes a strong interference with the person's private life and human dignity. This kind of degrading treatment should not be accepted in the European Union, nor elsewhere."<ref>{{Cite web|url=https://euobserver.com/health-and-society/32349|title=Czech sexuality tests not legal, EU commission says|date=May 17, 2011|website=EUobserver}}</ref> The Czech Interior Ministry replied that the testing was conducted only after written consent has been obtained, and when it was not possible to use a different method of verification. According to the Ministry, all those who had passed the test had been granted asylum.<ref>{{Cite web|url=https://www.thestar.com/news/world/2010/12/08/czech_republic_defends_test_of_gay_asylum_seekers_despite_eu_criticism.html|title=Czech Republic defends test of gay asylum seekers despite EU criticism|date=December 8, 2010|website=thestar.com}}</ref>
A roughly equivalent procedure for women, ]y, measures blood through the walls of the ], which researchers claim increases during sexual arousal.


==See also== ==See also==
*] * ]
* ]
* ]
* ]
* ]
* ]


==References== ==References==
{{reflist|30em}}
<div class="references-small"> <references/> </div>


==External links== ==Further reading==
* {{cite book |last1=Laws |first1=D. Richard |title=A History of the Assessment of Sex Offenders: 1830–2020 |chapter=Penile Plethysmography: The Search for the Gold Standard |date=14 February 2020 |pages=113–128 |doi=10.1108/978-1-78769-359-320201016|isbn=978-1-78769-360-9 |s2cid=213674579 }}
* {{cite book |last1=Plaud |first1=Joseph J. |title=Sexually Violent Predators: A Clinical Science Handbook |chapter=The Use of Penile Plethysmography in SVP Assessment and Treatment Decision-Making |date=2019 |pages=243–254 |doi=10.1007/978-3-030-04696-5_15|isbn=978-3-030-04695-8 |s2cid=198790600 }}

{{Male genital procedures}}


*
*
*
*
*
*
] ]
] ]
] ]
] ]
]

]
]

Latest revision as of 00:06, 26 February 2024

Measurement of bloodflow to the penis Medical intervention
Penile plethysmograph
Other namesPhallometry
ICD-9-CM89.58
[edit on Wikidata]

Penile plethysmography (PPG) or phallometry is a measurement of blood flow to the penis, typically used as a proxy for measurement of sexual arousal. The most commonly reported methods of conducting penile plethysmography involves the measurement of the circumference of the penis with a mercury-in-rubber or electromechanical strain gauge, or the volume of the penis with an airtight cylinder and inflatable cuff at the base of the penis. Corpora cavernosa nerve penile plethysmographs measure changes in response to inter-operative electric stimulation during surgery. The volumetric procedure was invented by Kurt Freund and is considered to be particularly sensitive at low arousal levels. The easier to use circumferential measures are more widely used, however, and more common in studies using erotic film stimuli. A corresponding device in women is the vaginal photoplethysmograph.

For sexual offenders it is typically used to determine the level of sexual arousal as the subject is exposed to sexually suggestive content, such as pictures, movies or audio, although some have argued that phallometry is not always appropriate for the evaluation of sexual preferences or treatment effects. A 1998 large-scale meta-analytic review of the scientific reports demonstrated that phallometric response to stimuli depicting children, though only having a .32 correlation with future sex offending (accounting for approximately 10% of the variance), had the highest accuracy among methods of identifying which sexual offenders will go on to commit new sexual crimes. (None of the methods were strong predictors with most accounting for far less than 10% of the variance).

In prostatectomy nerve-sparing surgery, the surgeon applies a mild electrical stimulation near the cavernous nerves of penis to verify their locations and avoid operative trauma. Damage to these difficult-to-see nerves can cause erectile dysfunction outcomes. At the surgery's conclusion, the electrical stimulation penile plethysmograph result is a prognosis which helps to manage the erectile function outcomes earlier than the many months required for recovery.

Types

This section needs additional citations for verification. Please help improve this article by adding citations to reliable sources in this section. Unsourced material may be challenged and removed.
Find sources: "Penile plethysmography" – news · newspapers · books · scholar · JSTOR (July 2021) (Learn how and when to remove this message)

There are two types of penile plethysmograph:

  • Volumetric air chamber
When this is placed over the subject's penis, as tumescence increases, the air displaced is measured.
  • Circumferential transducer
This uses a mercury-in-rubber or indium/gallium-in-rubber ring or electromechanical strain gauge and is placed around the shaft of the subject's penis to measure changes in circumference.

The circumferential type is more common, but the volumetric method is believed to be more accurate at low arousal levels.

Significant suppliers of PPG machines include Behavioral Technology Inc. and Medical Monitoring Systems. The device is known to be used in Brazil, Britain, Canada, China, Czech Republic, Hong Kong, New Zealand, Norway, Slovak Republic, Spain, and the United States.

The surgical machine is supplied as CaverMap by Blue Torch Medical Technology, Inc.

A roughly equivalent procedure for women, vaginal photoplethysmography, measures blood through the walls of the vagina, which researchers claim increases during sexual arousal.

Methodology

Exact procedures can vary, but in one study a seventeen-year-old male sex offender was, at the start of each daily session, privately fitted with a Parks Medical Electronics mercury strain gauge attached to his penis and worn under trousers and underwear. The device had previously been calibrated with measurements from his penis in its flaccid state and at full erection as achieved through masturbation. This device was connected to a microprocessor, a battery pack, and a strain gauge amplifier, all of which were kept discreetly in a fanny pack. He was then driven daily to a college campus for multiple sessions to assess his sexual attraction to women and men, who were about 30–100 feet away from him. While remaining in a parked car, he was instructed to focus on either a specific woman or a specific man in the setting, imagine himself having sex with them, and allow himself to become sexually aroused if he was so inclined. The device then measured the percentage of full erection that he achieved. This was repeated over a period of 24 days, with the results showing a significantly greater level of attraction to women, especially when research staff were discreetly absent.

History

The original volumetric was developed during the 1950s by Kurt Freund in then-Czechoslovakia. Freund later wrote, "In the early fifties homosexual interaction was still an indictable offense in Czechoslovakia. I was of course opposed to this measure, but I still thought, as did my colleagues at the psychiatric university hospital in Prague where I was working, that homosexuality was an experientially acquired neurosis". He then developed phallometry to replace psychoanalytic methods of assessment because "sychoanalysis had turned out to be a failure, virtually unusable as an instrument for individual diagnosis or research....When phallometry began to look promising as a test of erotic sex and age preferences, we started using it mainly as a test of pedophilia, that is determining who has an erotic preference for children over adults".

In post–World War II Czechoslovakia, Freund was assigned by the communist government the task of identifying among military conscripts men who were falsely declaring themselves to be gay to avoid the draft. "Freund (1957) developed the first device, which measured penile volume changes... to distinguish heterosexual and homosexual males for the Czechoslovakian army." When he escaped Europe for Canada, Freund was able to pursue his research using phallometry for the assessment of sexual offenders. At that time, attempts to develop methods of changing homosexual men into heterosexual men were being made by many sexologists, including John Bancroft, Albert Ellis, and William Masters of the Masters and Johnson Institute. Because phallometry showed that such methods were failures, Freund was among the first sexologists to declare that such attempts were unethical. Based primarily on Freund's studies, decriminalization of homosexuality took place in Czechoslovakia in 1961. (See also LGBT rights in the Czech Republic.)

Reliability and validity

In 1994, the Diagnostic and Statistical Manual of Mental Disorders (Fourth Edition) of the American Psychiatric Association stated that penile plethysmography has been used in research settings to assess various paraphilias by measuring an individual's sexual arousal in response to visual and auditory stimuli. The reliability and validity of this procedure in clinical assessment have not been well established, and clinical experience suggests that subjects can simulate response by manipulating mental images." In contrast, a 2017 recent meta-analysis provides support for the validity of phallometric testing as a measure of sexual interests in children across 37 samples and 6,785 individuals.

In 1998, Hanson and Bussière published a comprehensive meta-analysis of 61 scientific reports on the prediction of sexual offenses spanning more than 40,000 individual cases. They ascertained that of all the methods attempted and reported, penile phethysmographic responses to imagery depicting children was the single most accurate predictor of sexual re-offense across 7 studies reporting data from phallometric testing. Another meta-analysis in 2005 of 13 studies and 2,180 individual cases repeated the finding that phallometric responses to children was a strong predictor of sexual re-offense.

A 2017 meta-analysis that included 16 samples and 2,709 sexual offenders replicated and extended the previous findings that phallometric responding to children is a predictor of sexual re-offence. This meta-analysis extended previous meta-analytic research by showing phallometric responding to both male and female pedophilic and hebephilic stimuli predict sexual re-offence. Further, this meta-analysis showed that phallometric testing predicts sexual re-offence in distinct subgroups of sexual offenders against children.

Critique of methodological problems

There are criticisms of the methodology used to determine the reliability and specificity of penile plethysmography. One such criticism is that while penile plethysmography is said to be important for being more objective than a test subject's subjective reports on sexual arousal, the argument for penile plethysmography being a more reliable gauge of sexual arousal than vaginal plethysmography is still that there is a higher correspondence on average between what the test subjects report and what the instruments observe in male subjects than in female subjects. There is a criticism of this discrepancy for lacking consistency in the standards of whether or not subjective reports are useful. There is also criticism regarding the possibility of sampling bias being greater in male subjects of penile plethysmography than in female subjects of vaginal plethysmography, males being generally more aware of their physical sexual responses than females in most cultures may cause the male volunteers to be almost exclusively individuals who have category specific erections due to those with nonspecific erections fearing erection in taboo contexts and therefore not signing up for the studies. This effect may explain apparent male specificity as a result of methodological bias. The difference between tests of volunteers and tests of convicted or suspected sex offenders in penile plethysmography results may be caused by the sex offender group often effectively lacking the choice not to volunteer, without difference in erection patterns from the average population. One criticism of reoffending studies is that cultural attitudes that assume that men are sexually attracted to what they phallometrically respond to may cause men with no actual sexual interest in children to identify as pedophiles due to knowing that they phallometrically respond to them, making them more likely to be convicted again.

Utility

Erectile dysfunction

The penile plethysmograph has value in screening organic versus psychogenic erectile dysfunction in urological polysomnography centres. Lack of sexual response during REM sleep may indicate that further evaluation by a urologist is required.

When applied during nerve-sparing surgery, electrical stimulation penile plethysmograph is an erectile dysfunction prognostic. The patient is provided with objective information on his specific outcome which aids in planning for further erectile function therapies.

Pedophilia, hebephilia, pedohebephilia, and ephebophilia

Studies examining the efficiency of using penile plethysmograph to distinguish pedophilic men from non-pedophilic men, including hebephiles, show that a majority can be correctly assigned to the proper category. Sensitivity of a phallometric test is defined as the accuracy of the test to identify pedophilic (or hebephilic) individuals as having these sexual interests. Specificity of these tests is defined as the accuracy of the test to identify non-pedophilic (or non-hebephilic) individuals as such. Meta-analytic research has shown that sexual offenders against children show greater responding on phallometric tests for pedophilia and hebephilia than controls.

Volumetric penile plethysmography

In one study, 21% of the subjects were excluded for various reasons, including "the subject's erotic age-preference was uncertain and his phallometrically diagnosed sex-preference was the same as his verbal claim" and attempts to influence the outcome of the test. This study found the sensitivity for identifying pedohebephilia in sexual offenders against children admitting to this interest to be 100%. In addition, the sensitivity for this phallometric test in partially admitting sexual offenders against children was found to be 77% and for denying sexual offenders against children to be 58%. The specificity of this volumetric phallometric test for pedohebephilia was estimated to be 95%.

Further studies by Freund have estimated the sensitivity of a volumetric test for pedohebephilia to be 35% for sexual offenders against children with a single female victim, 70% for those with two or more female victims, 77% for those offenders with one male victim, and 84% for those with two or more male victims. In this study, the specificity of the test was estimated to be 81% in community males and 97% in sexual offenders against adults. In a similar study, the sensitivity of a volumetric test for pedophilia to be 62% for sexual offenders against children with a single female victim, 90% for those with two or more female victims, 76% for those offenders with one male victim, and 95% for those with two or more male victims.

In a separate study, sensitivity of the method to distinguish between pedohebephilic men from non-pedohebephilic men was estimated between 29% and 61% depending on subgroup. Specifically, sensitivity was estimated to be 61% for sexual offenders against children with three or more victims and 34% in incest offenders. The specificity of the test using a sample of sexual offenders against adults was 96% and the area under the curve for the test was estimated to be .86. Further research by this group found the specificity of this test to be 83% in a sample of non-offenders. More recent research has found volumetric phallometry to have a sensitivity of 72% for pedophilia, 70% for hebephilia, and 75% for pedohebephilia and a specificity of 95%, 91%, and 91% for these paraphilias, respectively.

Circumferential penile plethysmography

Other studies have examined the sensitivity and specificity of circumferential phallometry to identify different sexual interests in children. Sensitivity for a circumferential phallometric test for pedophilia has been estimated to be 63% in sexual offenders against children, 65% in extrafamilial offenders against children and 68.4% in incest offenders. Additional research has found different circumferential phallometric tests to have a sensitivity of 93%, 96%, 35%, 78%, and 50% in sexual offenders against children. In incest offenders, the sensitivity of circumferential phallometric tests has been estimated as 19% and 60% in extrafamilial offenders against children. In terms of specificity of these tests for pedophilia, research has estimated the specificity as 92%, 82%, 76%, and 92% in samples of community males and 80% and 92% in sexual offenders against adults.

A single study has examined the accuracy of a circumferential phallometric test for hebephilia. This study found the sensitivity of the hebephilia test to be 70% in extrafamilial offenders against children and 52% in incest offenders. In addition, the specificity for this phallometric test was 68% in a sample of community males.

Other studies have found different phallometric tests for pedohebephilia to have a sensitivity of 75% in incest offenders, 67% in extrafamilial offenders against children, and 64%, 64%, 44%, and 53%, in sexual offenders against children.

In addition, Abel and colleagues found ephebophilic stimuli to have a sensitivity of 50%.

Another study examined the possibility that juvenile sex offenders might be able to suppress arousal deemed deviant. Of the juveniles who exhibited sexual arousal, categorization was made into two age appropriate categories—Adult and Peer responders—and three age inappropriate categories—Child, Child/Adult, and Nondiscriminating responders—based on whether they had the greatest sexual arousal in response to adult female, peer female, or younger child female stimuli. Sexual arousal in response to older adult women or peers was deemed age appropriate; sexual arousal in response to significantly younger females was deemed inappropriate. Many of the juveniles who denied responsibility for their offenses showed no sexual arousal at all—however about one-third still showed age inappropriate arousal despite denying responsibility for their offenses.

Biastophilia

There is some evidence that phallometry can distinguish groups of men with biastophilia (a paraphilia involving rape) from groups of men without it.

Legal admissibility

In general, phallometric test results are employed as part of the sentencing and rehabilitation phase of forensic systems, but not for determining whether a specific defendant is guilty of any specific offense against any specific person.

United States

Use as trial evidence

In the United States, a scientific technique could not be used as evidence in court unless the technique was "generally accepted" as reliable in the relevant scientific community. This was known as the Frye standard, adopted in 1923. In 1993, the doctrine was rejected by the Supreme Court of the United States in favor of a more comprehensive "reliable foundation" test in Daubert v. Merrell Dow Pharmaceuticals. In the Daubert standard, the "generally accepted" test was no longer determinative. Several other factors could now be considered, including whether the technique had been published and peer-reviewed. Myers notes, "Courts that have considered penile plethysmography generally rule that the technique is not sufficiently reliable for use in court."

In United States v. Powers the court excluded the penile plethysmograph test because it failed to qualify under Daubert's scientific validity prong for two reasons: the scientific literature does not regard the test as a valid diagnostic tool, and "a vast majority of incest offenders who do not admit their guilt, such as Powers, show a normal reaction to the test. The Government argues that such false negatives render the test unreliable."

According to Barker and Howell, penile plethysmography (PPG) does not meet the legal threshold for the guilt phase for the following reasons:

  • No standardization
  • Test results are not sufficiently accurate
  • Results are subject to faking and voluntary control by test subjects
  • High incidence of false negatives and false positives
  • Results are open to interpretation

They concluded, "Until a way can be devised to detect and/or control false negatives and false positives, the validity of the test data will be questionable." Responding to Barker and Howell, Simon and Schouten noted, "Our own analysis suggests that the standardization and faking issues, as well as other problems not addressed in the Barker and Howell paper, warrant much more guarded conclusions about the use of the plethysmograph in legal and clinical settings." Prentky noted "the increased likelihood in forensic settings that dissimulation may compromise the validity of the assessment." Hall and Crowther noted penile plethysmography "may be even more problematic than other in assessing susceptibility of the test to faking."

In State of North Carolina v. Spencer, the court reviewed the literature and case law and concluded that penile plethysmography was scientifically unreliable: "Despite the sophistication of the current equipment technology, a question remains whether the information emitted is a valid and reliable means of assessing sexual preference."

More recently, a substantial amount of research data has been gathered and reviewed, and significant steps have been taken toward standardization. According to researcher Gilles Launay, "he validity of the technique for research and clinical assessment is now established;" it is only the use in guilt-determination proceedings that is inappropriate. Fedoroff and Moran called it an "experimental procedure" and noted, "Virtually every expert who has written about phallometry has cautioned that it is insufficiently sensitive or specific to be used to determine the guilt or innocence of a person accused of a sex crime."

Post-conviction use

Phallometry is widely considered appropriate for treatment and supervision of convicted sex offenders: "Courts have permitted plethysmographic testing for monitoring compliance by convicted sex offenders with the conditions of their community placement as part of crime-related treatment for sexual deviancy." Its use for the treatment and management of sexual offenders is recommended by the Association for the Treatment of Sexual Abusers. Becker notes it "should never be used exclusively in forensic decision making." The sexual assault trial of basketball player Kobe Bryant in Colorado brought this device and its use to public attention before the case was dropped in 2004, because Colorado law would have required evaluation with this device following conviction. The United States Court of Appeals for the Ninth Circuit recently addressed the procedures required before a federal supervised release program could include penile plethysmograph testing. The device is routinely used at civil commitment facilities, but "some clinicians and offenders say it is easy, particularly in a laboratory, to stifle arousal and thus cheat on a plethysmograph test." This has been reported to occur in 16% of cases.

During the Catholic sex abuse cases, the reliability of the test was questioned by some officials in the Roman Catholic Archdiocese of Philadelphia. Later, these officials chose to seek therapy at an institution where the plethysmograph was not used.

Canada

This article's tone or style may not reflect the encyclopedic tone used on Misplaced Pages. See Misplaced Pages's guide to writing better articles for suggestions. (November 2023) (Learn how and when to remove this message)

Courts in Canada came to a similar conclusion as those in the United States. The Supreme Court of Canada adopted the Daubert doctrine in R. v . J.-L.J. 2 S.C.R. 600, which upheld a lower court's decision to exclude testimony by a psychiatrist who had administered several tests on the accused, including a penile plethysmograph:

A level of reliability that is quite useful in therapy because it yields some information about a course of treatment is not necessarily sufficiently reliable to be used in a court of law to identify or exclude the accused as a potential perpetrator of an offence. In fact, penile plethysmography has received a mixed reception in Quebec courts: Protection de la jeunesse – 539, R.J.Q. 1144; R. c. Blondin, Q.J. No. 3605 (QL) (S.C.); L. Morin and C. Boisclair in "La preuve d'abus sexuel: allégations, déclarations et l'évaluation d'expert" (1992), 23 R.D.U.S. 27. Efforts to use penile plethysmography in the United States as proof of disposition have largely been rejected: People v. John W., 185 Cal.App.3d 801 (1986); Gentry v. State, 443 S.E.2d 667 (Ga. Ct. App. 1994); United States v. Powers, 59 F.3d 1460 (4th Cir. 1995); State v. Spencer, 459 S.E.2d 812 (N.C. App. 1995); J. E. B. Myers et al., "Expert Testimony in Child Sexual Abuse Litigation" (1989), 68 Neb. L. Rev. 1, at pp. 134-35; J. G. Barker and R. J. Howell, "The Plethysmograph: A Review of Recent Literature" (1992), 20 Bull. Am. Acad. of Psychiatry & L. 13.

— 

As of 2010, all youth in sex offender treatment programs administered by the Youth Forensic Psychiatric Service of British Columbia were offered a voluntary penile plethysmograph test to predict whether they can properly control their deviant arousal, or whether they will require medication or other forms of treatment. According to sceptics, however, the test does not reliably predict recurrent violations.

Ethics and legality of use

Robert Todd Carroll writes, "More objectionable than the questionable scientific validity of the device, however, are the moral and legal questions its use raises." Carroll and others cite the legality of the depictions of minors, as well as the constitutionality of requiring PPG for admission to jobs or the military, or in custody cases. In Harrington v. Almy the United States Court of Appeals for the First Circuit found that a PPG ordered to be administered by William O'Donohue as a precondition of employment was a violation of plaintiff's rights under the Fourteenth Amendment to the United States Constitution. In a 2009 report led by Robert Clift on use of the device on adolescent offenders, the authors acknowledge in their conclusions that PPG tests "are problematic ethically and should be used only after therapists have carefully weighed the benefits versus the negatives." The Minister of Children and Family Development closed the program examined in Clift's report in 2010 following complaints by civil rights groups. The principal manufacturer of the device stopped making them in the 1990s.

The EU's leading human rights agency, the Fundamental Rights Agency, has criticised the use of phallometric tests by the Czech Republic to determine whether asylum seekers presenting themselves as homosexual were in fact gay. According to the Agency, the Czech Republic was in 2010 the only EU country to employ a sexual arousal test, which the Agency said could violate the European Convention on Human Rights. In 2011 the EU commission issued a statement calling the Czech practice illegal, saying "The practice of phallometric tests constitutes a strong interference with the person's private life and human dignity. This kind of degrading treatment should not be accepted in the European Union, nor elsewhere." The Czech Interior Ministry replied that the testing was conducted only after written consent has been obtained, and when it was not possible to use a different method of verification. According to the Ministry, all those who had passed the test had been granted asylum.

See also

References

  1. Prause, Nicole, and Erick Janssen. "Blood flow: Vaginal photoplethysmography." Women's sexual function and dysfunction: Study, diagnosis, and treatment (2006): 359-367.
  2. ^ Simon W. T.; Schouten P. G. (1992). "The plethysmograph reconsidered: Comments on Barker and Howell". Bulletin of the American Academy of Psychiatry and the Law. 20: 13–25.
  3. ^ Hanson R. K.; Bussière M. T. (1998). "Predicting relapse: A meta-analysis of sexual offender recidivism studies". Journal of Consulting and Clinical Psychology. 66 (2): 348–362. doi:10.1037/0022-006x.66.2.348. PMID 9583338.
  4. Klotz L, Heaton J, Jewett M, et al. (November 2000). "A randomized phase 3 study of intraoperative cavernosa nerve stimulation with penile tumescence monitoring to improve nerve sparing during radical prostatectomy". J. Urol. 164 (5): 1573–8. doi:10.1016/S0022-5347(05)67031-0. PMID 11025707.
  5. Howes R. J. (1995). "A survey of plethysmographic assessment in North America". Sexual Abuse: A Journal of Research and Treatment. 7: 9–24. doi:10.1007/bf02254871. S2CID 195271489.
  6. Kuban M, Barbaree HE, Blanchard R (August 1999). "A comparison of volume and circumference phallometry: response magnitude and method agreement" (PDF). Arch Sex Behav. 28 (4): 345–59. doi:10.1023/A:1018700813140. PMID 10553495. S2CID 37559615.
  7. Rea, Jerry; DeBriere, Terry; Butler, Kasey; Saunders, Kathryn (1998). "An Analysis of Four Sexual Offenders' Arousal in the Natural Environment Through the Use of a Portable Penile Plethysmograph". Sexual Abuse: A Journal of Research and Treatment. 10 (3): 239–255. doi:10.1177/107906329801000307. S2CID 145083086.
  8. Freund K (1991). "Reflections on the development of the phallometric method of assessing sexual preference". Annals of Sex Research. 4 (3–4): 221–228. doi:10.1007/BF00850054. S2CID 145609210.
  9. ^ Wilson, R. J., & Mathon, H. F. (2006, fall). Remembering Kurt Freund (1914-1996). ATSA Forum. Beaverton, OR: Association for the Treatment of Sexual Abusers.
  10. "penile plethysmograph (PPG) - The Skeptic's Dictionary - Skepdic.com". skepdic.com.
  11. W O'Donohue, E Letourneau. The psychometric properties of the penile tumescence assessment of child molesters. Journal of Psychopathology and Behavioral Assessment, 1992
  12. Bancroft J (December 1969). "Aversion therapy of homosexuality. A pilot study of 10 cases". Br J Psychiatry. 115 (529): 1417–31. doi:10.1192/bjp.115.529.1417. PMID 5358532. S2CID 9427323.
  13. Ellis A (1956). "The effectiveness of psychotherapy with individuals who have severe homosexual problems". Journal of Consulting Psychology. 20 (3): 191–195. doi:10.1037/h0044762. PMID 13357645.
  14. Schwartz MF, Masters WH (February 1984). "The Masters and Johnson treatment program for dissatisfied homosexual men". Am J Psychiatry. 141 (2): 173–81. doi:10.1176/ajp.141.2.173. PMID 6691475.
  15. "Archived copy". Archived from the original on 2010-01-02. Retrieved 2008-05-30.{{cite web}}: CS1 maint: archived copy as title (link)
  16. DSM-IV, p. 524.
  17. ^ McPhail, Ian V.; Hermann, Chantal A.; Fernane, Stephanie; Fernandez, Yolanda M.; Nunes, Kevin L.; Cantor, James M. (2017). "Validity in Phallometric Testing for Sexual Interests in Children: A Meta-Analytic Review". Assessment. 26 (3): 535–551. doi:10.1177/1073191117706139. PMID 28454493. S2CID 35657151.
  18. Hanson R. K.; Morton-Bourgon K. E. (2005). "The characteristics of persistent sexual offenders: A meta-analysis of recidivism studies". Journal of Consulting and Clinical Psychology. 73 (6): 1154–1163. doi:10.1037/0022-006x.73.6.1154. hdl:10983/26131. PMID 16392988. S2CID 14984239.
  19. Science and Pseudoscience in Clinical Psychology, Scott O. Lilienfeld, Steven Jay Lynn, Jeffrey M. Lohr 2015
  20. At the Fringes of Science, 1998, Michael W. Friedlander
  21. "Plural-characteristic-measuring radial erectometer".
  22. Marshall P, Surridge D, Delva N (February 1981). "The role of nocturnal penile tumescence in differentiating between organic and psychogenic impotence: the first stage of validation". Arch Sex Behav. 10 (1): 1–10. doi:10.1007/BF01542669. PMID 7212992. S2CID 9912262.
  23. Klotz L (January 2004). "Cavernosal nerve mapping: current data and applications". BJU Int. 93 (1): 9–13. doi:10.1111/j.1464-410X.2004.04546.x. PMID 14678359.
  24. ^ Blanchard R, Klassen P, Dickey R, Kuban ME, Blak T (March 2001). "Sensitivity and specificity of the phallometric test for pedophilia in nonadmitting sex offenders". Psychol Assess. 13 (1): 118–26. doi:10.1037/1040-3590.13.1.118. PMID 11281033.
  25. ^ Freund K, Blanchard R (February 1989). "Phallometric diagnosis of pedophilia". J Consult Clin Psychol. 57 (1): 100–5. doi:10.1037/0022-006X.57.1.100. PMID 2925958.
  26. Murphy, W. & Barbaree, H. E. (1994). Assessments of sexual offender by measures of erectile response: Psychometric properties and decision making. Brandon, VT: Safer Society Press.
  27. Freund, K.; Watson, R. J. (1991). "Assessment of the sensitivity and specificity of a phallometric test: An update of phallometric diagnosis of pedophilia". Psychological Assessment. 3 (2): 254–260. doi:10.1037/1040-3590.3.2.254.
  28. Freund, K.; Watson, R. J. (1992). "The proportions of heterosexual and homosexual pedophiles among sex offenders against children: An exploratory study". Journal of Sex & Marital Therapy. 18 (1): 34–43. doi:10.1080/00926239208404356. PMID 1556756.
  29. Blanchard, R.; Kuban, M. E.; Blak, T.; Cantor, J. M.; Klassen, P; Dickey, R (2006). "Phallometric comparison of pedophilic interest in nonadmitting sexual offenders against stepdaughters, biological daughters, other biologically related girls, and unrelated girls". Sexual Abuse: A Journal of Research and Treatment. 18 (1): 1–14. CiteSeerX 10.1.1.1016.1030. doi:10.1177/107906320601800101. PMID 16598663. S2CID 220355661.
  30. Cantor, James; McPhail, Ian (2015). "Sensitivity and specificity of the phallometric test for hebephilia". Journal of Sexual Medicine. Online first (9): 1940–1950. doi:10.1111/jsm.12970. PMID 26272778.
  31. ^ Abel, G. G.; Huffman, J.; Warberg, B.; Holland, C. L. (1998). "Visual reaction time and plethysmography as measures of sexual interest in child molesters". Sexual Abuse: A Journal of Research and Treatment. 10 (2): 81–95. doi:10.1177/107906329801000202. S2CID 220352804.
  32. Barsetti, I.; Earls, C. M.; Lalumiere, M. L.; Belanger, N. (1998). "The differentiation of intrafamilial and extrafamilial heterosexual child molesters". Journal of Interpersonal Violence. 13 (2): 275–286. doi:10.1177/088626098013002007. S2CID 144592544.
  33. Chaplin, T. C; Rice, M. E.; Harris, G. T. (1995). "Salient victim suffering and the sexual responses of child molesters". Journal of Consulting and Clinical Psychology. 63 (2): 249–255. doi:10.1037/0022-006x.63.2.249. PMID 7751485.
  34. ^ Harris, G. T.; Rice, M. E.; Quinsey, V. L.; Chaplin, T. C. (1996). "Viewing time as a measure of sexual interest among child molesters and normal heterosexual men". Behaviour Research and Therapy. 34 (4): 389–394. doi:10.1016/0005-7967(95)00070-4. PMID 8871372.
  35. ^ Looman, J.; Marshall, W. L. (2001). "Phallometric assessment designed to detect arousal to children: The responses of rapists and child molesters". Sexual Abuse: A Journal of Research and Treatment. 13 (1): 3–13. doi:10.1177/107906320101300102. S2CID 144505915.
  36. ^ Muller, K.; Curry, S.; Ranger, R.; Briken, P.; Bradford, J.; Federoff, J. P. (2014). "Changes in sexual arousal as measured by penile plethysmography in men with pedophilic sexual interests". Journal of Sexual Medicine. 11 (5): 1221–1229. doi:10.1111/jsm.12488. PMID 24636071.
  37. ^ Wormith, S (1986). "Assessing deviant sexual arousal: Physiological and cognitive aspects". Advances in Behaviour Research and Therapy. 8 (3): 101–137. doi:10.1016/0146-6402(86)90001-9.
  38. ^ Marshall, W. L.; Barbaree, H. E.; Christophe, D. (1986). "Sexual offenders against female children: Sexual preferences for age of victims and type of behaviour". Canadian Journal of Behavioural Science. 18 (4): 424–439. doi:10.1037/h0079966.
  39. Fernandez, Yolanda (2001). "Phallometric testing with sexual offenders against female and male victims: An examination of reliability and validity issues". Unpublished Doctoral Dissertation.
  40. Goyette, M. (2012). "Évaluation des intérêts sexuels auprès d'agresseurs sexuels d'enfants par la vidéo-oculographie et la présentation de stimuli générés par ordinateur". Unpublished Doctoral Dissertation.
  41. Gray, S. R.; Plaud, J. J. (2005). "A comparison of the Abel Assessment for Sexual Interests and penile plethysmography in an outpatient sample of sexual offenders". Journal of Sexual Offender Civil Commitment: Science and the Law. 1: 1–10.
  42. Malcolm, P. B.; Andrews, D. A.; Quinsey, V. L. (1993). "Discriminant and predictive validity of phallometrically measured sexual age and gender preference". Journal of Interpersonal Violence. 8 (4): 486–501. doi:10.1177/088626093008004004. S2CID 144688361.
  43. Becker J.V.; Kaplan M; Tenke C (Winter 1992). "The Relationship of Abuse History, Denial and Erectile Response Profiles of Adolescent Sexual Perpetrators". Behavior Therapy. 23 (1): 87–97. doi:10.1016/s0005-7894(05)80310-7.
  44. Seto M. C.; Kuban M. (1996). "Criterion-related validity of a phallometric test for paraphilic rape and sadism". Behaviour Research and Therapy. 34 (2): 175–183. doi:10.1016/0005-7967(95)00056-9. PMID 8741725.
  45. Myers JEB (2005). Myers on Evidence in Child, Domestic, and Elder Abuse Cases. Aspen Publishers Online ISBN 0-7355-5668-7
  46. United States v. Powers, 59 F.3d 1460 (4th Cir. 1995)
  47. ^ Barker James G., Howell Robert J. (1992). "The Plethysmograph: A Review of Recent Literature". Journal of the American Academy of Psychiatry and the Law. 20 (1): 13–25. PMID 1576372.
  48. Prentky RA, Knight RA, Lee AFS (1997) Risk factors associated with recidivism among extrafamilial child molesters. Journal of Consulting and Clinical Psychology.
  49. Hall GCN, Crowther JH (1991). Psychologists' involvement in cases of child maltreatment: additional limits of assessment methods. American Psychologist Jan Vol 46(1) 79-80
  50. North Carolina v. Spencer, 459 S.E.2d 812, 815 (N.C. Ct. App. 1995),
  51. Launay, G. (1999). "The phallometric assessment of sex offenders: an update". Criminal Behaviour and Mental Health. 9 (3): 254–274. doi:10.1002/cbm.317.
  52. Fedoroff, JP; Moran, B (1997). "Myths and Misconceptions about Sex Offenders". The Canadian Journal of Human Sexuality. 6: 1997.
  53. Sachsenmaier, S. J., & Peters, J. M. (2002). Sexual offender risk assessment methods and admissibility as expert witness evidence. In J. M. Peters (Ed.), Assessment and management of sex offenders: What prosecutors need to know. Washington, DC: United States Department of Justice, Child Exploitation and Obscenity Section
  54. Association for the Treatment of Sexual Abusers. (2004). ATSA Practice Standards and Guidelines for the evaluation, treatment and management of adult male sexual abusers. Beaverton, OR: Author.
  55. Becker J.V., Murphy WD (1998). What we know and do not know about assessing and treating sex offenders. Psychology, Public Policy, and Law. Volume:4 Issue:1/2 Dated:March/June 1998 Pages:116 to 137
  56. Mark Shaw for USATODAY- Bryant's off-court issues may aid prosecution
  57. United States v. Weber, 2006 U.S. App. LEXIS 15111 (9th Cir. 2006).
  58. Goodnough A, Davey M (March 6, 2007). For Sex Offenders, a Dispute Over Therapy's Benefits. New York Times
  59. Court of Common Pleas, First Judicial District of PA, County Investigating Grand Jury, 9-17-2003
  60. R. v . J.-L.J. Archived 2008-10-02 at the Wayback Machine, 2 S.C.R. 600
  61. Adrian MacNair: B.C. government rethinks penis-arousal tests (National Post, July 29, 2010) Archived July 11, 2012, at archive.today
  62. Carroll, Robert Todd (2003). Penile plethysmograph (PPG). The skeptic's dictionary: a collection of strange beliefs, amusing deceptions, and dangerous delusions, pp. 278-281. John Wiley and Sons, ISBN 978-0-471-27242-7
  63. Harrington v. Almy, 977 F.2d 37 (1st Cir.1992)
  64. Ford, Royal (June 19, 1993). Maine officer who refused sex response test wins suit. Boston Globe
  65. Clift, JRW; Rajlic, G; Gretton, H (2009). "Discriminative and Predictive Validity of the Penile Plethysmograph in Adolescent Sex Offenders". Sexual Abuse. 21 (3): 335–362. doi:10.1177/1079063209338491. PMID 19587382. S2CID 7328366.
  66. Bula, Frances (July 27, 2010). B.C. rights group complains about testing of young sex offenders. The Globe and Mail
  67. Staff report (August 8, 2010). B.C. used penile teen sex test for decades. CBC News
  68. Wintonyk, Darcy (July 29, 2010). B.C. permanently halts sexual arousal testing. CTV News
  69. Hyde, Alan (1997). The legal penis. Bodies of Law, pp. 173 ff. Princeton University Press, ISBN 978-0-691-01228-5
  70. "Czech gay asylum 'phallometric test' criticised by EU". BBC News. December 8, 2010.
  71. "Czech sexuality tests not legal, EU commission says". EUobserver. May 17, 2011.
  72. "Czech Republic defends test of gay asylum seekers despite EU criticism". thestar.com. December 8, 2010.

Further reading

Tests and procedures involving the male reproductive system
Prostate
Seminal vesicles
Vas deferens
Testes
Penis
Other tests
Categories: