Revision as of 22:09, 3 February 2023 editBob K (talk | contribs)Extended confirmed users6,614 editsm →Examples of normalization: add instances of {{mvar}} template← Previous edit | Revision as of 20:18, 5 February 2023 edit undoBob K (talk | contribs)Extended confirmed users6,614 edits →Examples of normalization: add a figureNext edit → | ||
Line 5: | Line 5: | ||
In ] (DSP), a '''normalized frequency''' is a ratio of a variable ] ({{math|''f''}}) and a constant frequency associated with a system (such as a '']'', {{math|''f''<sub>s</sub>}}). Some software applications require normalized inputs and produce normalized outputs, which can be re-scaled to physical units when necessary. Mathematical derivations are usually done in normalized units, relevant to a wide range of applications. | In ] (DSP), a '''normalized frequency''' is a ratio of a variable ] ({{math|''f''}}) and a constant frequency associated with a system (such as a '']'', {{math|''f''<sub>s</sub>}}). Some software applications require normalized inputs and produce normalized outputs, which can be re-scaled to physical units when necessary. Mathematical derivations are usually done in normalized units, relevant to a wide range of applications. | ||
] | |||
=== Examples of normalization === | === Examples of normalization === | ||
A typical choice of characteristic frequency is the '']'' ({{math|''f''<sub>s</sub>}}) that is used to create the digital signal from a continuous one. The normalized quantity, {{math|1=''f''{{′}} = ''f'' / ''f''<sub>s</sub>}}, has the unit ''cycle per sample'' regardless of whether the original signal is a function of time or distance. For example, when {{mvar|f}} is expressed in ] (''cycles per second''), {{math|''f''<sub>s</sub>}} is expressed in ''samples per second''.<ref>{{cite book |last=Carlson |first=Gordon E. |title=Signal and Linear System Analysis|publisher=©Houghton Mifflin Co |year=1992 |isbn=8170232384 |location=Boston, MA |pages=469, 490}}</ref> | A typical choice of characteristic frequency is the '']'' ({{math|''f''<sub>s</sub>}}) that is used to create the digital signal from a continuous one. The normalized quantity, {{math|1=''f''{{′}} = ''f'' / ''f''<sub>s</sub>}}, has the unit ''cycle per sample'' regardless of whether the original signal is a function of time or distance. For example, when {{mvar|f}} is expressed in ] (''cycles per second''), {{math|''f''<sub>s</sub>}} is expressed in ''samples per second''.<ref>{{cite book |last=Carlson |first=Gordon E. |title=Signal and Linear System Analysis|publisher=©Houghton Mifflin Co |year=1992 |isbn=8170232384 |location=Boston, MA |pages=469, 490}}</ref> |
Revision as of 20:18, 5 February 2023
Frequency divided by a characteristic frequencyIn digital signal processing (DSP), a normalized frequency is a ratio of a variable frequency (f) and a constant frequency associated with a system (such as a sampling rate, fs). Some software applications require normalized inputs and produce normalized outputs, which can be re-scaled to physical units when necessary. Mathematical derivations are usually done in normalized units, relevant to a wide range of applications.
Examples of normalization
A typical choice of characteristic frequency is the sampling rate (fs) that is used to create the digital signal from a continuous one. The normalized quantity, f′ = f / fs, has the unit cycle per sample regardless of whether the original signal is a function of time or distance. For example, when f is expressed in Hz (cycles per second), fs is expressed in samples per second.
Some programs (such as MATLAB toolboxes) that design filters with real-valued coefficients prefer the Nyquist frequency (fs/2) as the frequency reference, which changes the numeric range that represents frequencies of interest from cycle/sample to half-cycle/sample. Therefore, the normalized frequency unit is obviously important when converting normalized results into physical units.
A common practice is to sample the frequency spectrum of the sampled data at frequency intervals of fs/N, for some arbitrary integer N (see § Sampling the DTFT). The samples (sometimes called frequency bins) are numbered consecutively, corresponding to a frequency normalization by fs/N. The normalized Nyquist frequency is N/2 with the unit 1/N cycle/sample.
Angular frequency, denoted by ω and with the unit radians per second, can be similarly normalized. When ω is normalized with reference to the sampling rate as ω′ = ω / fs, the normalized Nyquist angular frequency is π radians/sample.
The following table shows examples of normalized frequency for f = 1 kHz, fs = 44100 samples/second (often denoted by 44.1 kHz), and 4 normalization conventions:
Quantity | Numeric range | Calculation | Reverse |
---|---|---|---|
f′ = f / fs | cycle/sample | 1000 / 44100 = 0.02268 | f = f′ × fs |
f′ = f / (fs/2) | half-cycle/sample | 1000 / 22050 = 0.04535 | f = f′ × fs / 2 |
f′ = f / (fs/N) | bins | 1000 × N / 44100 = 0.02268 N | f = f′ × fs / N |
ω′ = ω / fs | radians/sample | 1000 × 2π / 44100 = 0.14250 | ω = ω′ × fs |
See also
Citations
- Carlson, Gordon E. (1992). Signal and Linear System Analysis. Boston, MA: ©Houghton Mifflin Co. pp. 469, 490. ISBN 8170232384.