Misplaced Pages

Normalized frequency (signal processing): Difference between revisions

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
Browse history interactively← Previous editNext edit →Content deleted Content addedVisualWikitext
Revision as of 01:45, 11 January 2023 editQuondum (talk | contribs)Extended confirmed users36,927 edits Alternative normalizations: more spacing← Previous edit Revision as of 12:57, 11 January 2023 edit undoBob K (talk | contribs)Extended confirmed users6,614 edits partially undid my own changesTag: Visual editNext edit →
Line 11: Line 11:
== Alternative normalizations == == Alternative normalizations ==


Some programs (such as ] toolboxes) that design filters with real-valued coefficients prefer a characteristic frequency of {{math|''f''<sub>s</sub> / 2}} (the ]), which expands the upper limit of useful frequencies from {{math|1/2}} to {{math|1.}} The corresponding unit of frequency, shown in the table below, is ''half-cycle per sample''. Some programs (such as ] toolboxes) that design filters with real-valued coefficients prefer a characteristic frequency of {{math|''f''<sub>s</sub> / 2}} (the ]), which expands the upper limit of useful frequencies from {{math|1/2}} to {{math|1.}}


], denoted by {{math|''ω''}} and with the unit ], can be similarly normalized. When {{math|''ω''}} is normalized with reference to the sampling rate, the resulting unit is radian per sample. The normalized Nyquist angular frequency is ''π''&nbsp;radians/sample. ], denoted by {{math|''ω''}} and with the unit ], can be similarly normalized. When {{math|''ω''}} is normalized with reference to the sampling rate, the resulting unit is radian per sample. The normalized Nyquist angular frequency is ''π''&nbsp;radians/sample.
Line 28: Line 28:
|{{math|''f''<sub>s</sub>}} |{{math|''f''<sub>s</sub>}}
|&nbsp;{{math|size=150%|}}&nbsp; or &nbsp;&nbsp; |&nbsp;{{math|size=150%|}}&nbsp; or &nbsp;&nbsp;
|1000&nbsp;cycles/second ÷ 44100&nbsp;samples/second |1000&nbsp;cycles/second / 44100&nbsp;samples/second
|0.02268 cycle/sample |0.02268 cycle/sample
|- |-
Line 34: Line 34:
|{{math|''f''<sub>s</sub> / 2}} |{{math|''f''<sub>s</sub> / 2}}
|&nbsp;&nbsp; or &nbsp;&nbsp; |&nbsp;&nbsp; or &nbsp;&nbsp;
|1000&nbsp;cycles/second × 2&nbsp;half{{nbh}}cycles/cycle ÷ 44100&nbsp;samples/second |1000&nbsp;cycles/second / 22050&nbsp;samples/second
|0.04535&nbsp;half{{nbh}}cycle/sample |0.04535&nbsp;half{{nbh}}cycle/sample
|- |-
Line 40: Line 40:
|{{math|''f''<sub>s</sub> / 2π}} |{{math|''f''<sub>s</sub> / 2π}}
|&nbsp;&nbsp; or &nbsp;&nbsp; |&nbsp;&nbsp; or &nbsp;&nbsp;
|1000&nbsp;cycles/second × 2π&nbsp;radians/cycle ÷ 44100&nbsp;samples/second |1000&nbsp;cycles/second / 44100&nbsp;samples/second × 2π
|0.14250&nbsp;radian/sample |0.14250&nbsp;radian/sample
|} |}

Revision as of 12:57, 11 January 2023

Frequency divided by a characteristic frequency

In digital signal processing (DSP), a normalized frequency (f) is a quantity that is equal to the ratio of a frequency and a characteristic frequency of a system.

A typical choice of characteristic frequency is the sampling rate (fs) that is used to create the digital signal from a continuous one. The normalized quantity, f′ = f / fs, typically has the unit cycle per sample regardless of whether the original signal is a function of time, space, or something else. For example, when f is expressed in Hz (cycles per second), fs is expressed in samples per second.

This allows us to present concepts that are universal to all sample rates in a way that is independent of the sample rate. Such a concept is a digital filter design whose bandwidth is specified not in hertz, but as a percentage of the sample rate of the data passing through it. Formulas expressed in terms of fs (or Ts ≡ 1 / fs) are readily converted to normalized frequency by setting those parameters to 1. The inverse operation is usually accomplished by replacing instances of the frequency parameter, f, with f / fs or f Ts.

Alternative normalizations

Some programs (such as MATLAB toolboxes) that design filters with real-valued coefficients prefer a characteristic frequency of fs / 2 (the Nyquist frequency), which expands the upper limit of useful frequencies from 1/2 to 1.

Angular frequency, denoted by ω and with the unit radian per second, can be similarly normalized. When ω is normalized with reference to the sampling rate, the resulting unit is radian per sample. The normalized Nyquist angular frequency is π radians/sample.

The following table shows examples of normalized frequencies for a 1 kHz signal, a sampling rate fs = 44,100 samples/second (often denoted by 44.1 kHz), and 3 different choices of normalized units. Also shown is the frequency region containing one cycle of the discrete-time Fourier transform, which is always a periodic function.

Quantity Normalization Numeric range Computation Value
f fs    or    1000 cycles/second / 44100 samples/second 0.02268 cycle/sample
f fs / 2    or    1000 cycles/second / 22050 samples/second 0.04535 half‑cycle/sample
ω fs / 2π    or    1000 cycles/second / 44100 samples/second × 2π 0.14250 radian/sample

See also

Notes and citations

  1. Carlson, Gordon E. (1992). Signal and Linear System Analysis. Boston, MA: ©Houghton Mifflin Co. pp. 469, 490. ISBN 8170232384.