Revision as of 17:15, 3 February 2023 editBob K (talk | contribs)Extended confirmed users6,614 edits add a normalization optionTag: Visual edit: Switched← Previous edit | Revision as of 21:30, 3 February 2023 edit undoBob K (talk | contribs)Extended confirmed users6,614 edits →Examples of normalization: add a column to the tableNext edit → | ||
Line 14: | Line 14: | ||
], denoted by {{math|''ω''}} and with the unit '']'', can be similarly normalized. When {{math|''ω''}} is normalized with reference to the sampling rate as {{math|1=''ω''′ = ''ω'' / ''f''<sub>s</sub>}}, the normalized Nyquist angular frequency is ''π radians/sample''. | ], denoted by {{math|''ω''}} and with the unit '']'', can be similarly normalized. When {{math|''ω''}} is normalized with reference to the sampling rate as {{math|1=''ω''′ = ''ω'' / ''f''<sub>s</sub>}}, the normalized Nyquist angular frequency is ''π radians/sample''. | ||
The following table shows examples of normalized |
The following table shows examples of normalized frequency for {{math|''f''}} = 1 kHz, {{math|''f''<sub>s</sub>}} = 44100 ''samples/second'' (often denoted by ]), and 4 normalization conventions: | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 21: | Line 21: | ||
!'''Numeric range''' | !'''Numeric range''' | ||
!'''Calculation''' | !'''Calculation''' | ||
!'''Reverse''' | |||
|- | |- | ||
|{{math|1=''f'' / ''f''<sub>s</sub>}} | |{{math|1=''f''{{′}} = ''f'' / ''f''<sub>s</sub>}} | ||
| {{math||size=150%}} ''cycle/sample'' | | {{math||size=150%}} ''cycle/sample'' | ||
|1000 / 44100 = 0.02268 | |1000 / 44100 = 0.02268 | ||
|{{math|1=''f'' = ''f''{{′}} × ''f''<sub>s</sub>}} | |||
|- | |- | ||
|{{math|1=''f'' / (''f''<sub>s</sub>/2)}} | |{{math|1=''f''{{′}} = ''f'' / (''f''<sub>s</sub>/2)}} | ||
| ''half-cycle/sample'' | | ''half-cycle/sample'' | ||
|1000 / 22050 = 0.04535 | |1000 / 22050 = 0.04535 | ||
|{{math|1=''f'' = ''f''{{′}} × ''f''<sub>s</sub> / ''2''}} | |||
|- | |- | ||
|{{math|1=''f'' / (''f''<sub>s</sub>/''N'')}} | |{{math|1=''f''{{′}} = ''f'' / (''f''<sub>s</sub>/''N'')}} | ||
| {{math||size=150%}} ''bins'' | | {{math||size=150%}} ''bins'' | ||
|1000 × N / 44100 = 0.02268 N | |1000 × ''N'' / 44100 = 0.02268 ''N'' | ||
|{{math|1=''f'' = ''f''{{′}} × ''f''<sub>s</sub> / ''N''}} | |||
|- | |- | ||
|{{math|''ω'' / ''f''<sub>s</sub>}} | |{{math|1=''ω''{{′}} = ''ω'' / ''f''<sub>s</sub>}} | ||
| ''radians/sample'' | | ''radians/sample'' | ||
|1000 × 2π / 44100 = 0.14250 | |1000 × 2π / 44100 = 0.14250 | ||
|{{math|1=''ω'' = ''ω''{{′}} × ''f''<sub>s</sub>}} | |||
|} | |} | ||
Revision as of 21:30, 3 February 2023
Frequency divided by a characteristic frequencyIn digital signal processing (DSP), a normalized frequency is a ratio of a variable frequency (f) and a constant frequency associated with a system (such as a sampling rate, fs). Some software applications require normalized inputs and produce normalized outputs, which can be re-scaled to physical units when necessary. Mathematical derivations are usually done in normalized units, relevant to a wide range of applications.
Examples of normalization
A typical choice of characteristic frequency is the sampling rate (fs) that is used to create the digital signal from a continuous one. The normalized quantity, f′ = f / fs, has the unit cycle per sample regardless of whether the original signal is a function of time or distance. For example, when f is expressed in Hz (cycles per second), fs is expressed in samples per second.
Some programs (such as MATLAB toolboxes) that design filters with real-valued coefficients prefer the Nyquist frequency (fs/2) as the frequency reference, which changes the numeric range that represents frequencies of interest from cycle/sample to half-cycle/sample. Therefore, the normalized frequency unit is obviously important when converting normalized results into physical units.
A common practice is to sample the frequency spectrum of the sampled data at frequency intervals of fs/N, for some arbitrary integer N (see § Sampling the DTFT). The samples (sometimes called frequency bins) are numbered consecutively, corresponding to a frequency normalization by fs/N. The normalized Nyquist frequency is N/2 with the unit 1/N cycle/sample.
Angular frequency, denoted by ω and with the unit radians per second, can be similarly normalized. When ω is normalized with reference to the sampling rate as ω′ = ω / fs, the normalized Nyquist angular frequency is π radians/sample.
The following table shows examples of normalized frequency for f = 1 kHz, fs = 44100 samples/second (often denoted by 44.1 kHz), and 4 normalization conventions:
Quantity | Numeric range | Calculation | Reverse |
---|---|---|---|
f′ = f / fs | cycle/sample | 1000 / 44100 = 0.02268 | f = f′ × fs |
f′ = f / (fs/2) | half-cycle/sample | 1000 / 22050 = 0.04535 | f = f′ × fs / 2 |
f′ = f / (fs/N) | bins | 1000 × N / 44100 = 0.02268 N | f = f′ × fs / N |
ω′ = ω / fs | radians/sample | 1000 × 2π / 44100 = 0.14250 | ω = ω′ × fs |
See also
Citations
- Carlson, Gordon E. (1992). Signal and Linear System Analysis. Boston, MA: ©Houghton Mifflin Co. pp. 469, 490. ISBN 8170232384.