There has been considerable research showing the benefits of coronary stents. Data specifically on drug-eluting stents are less abundant, though where studied, they have usually been shown to be superior to bare-metal stents, and in some cases, may be used for lesions for which surgery was previously the only option. Drug-eluting stents are used both for restoring blood flow immediately after a heart attack and also electively for improving blood flow in a compromised vessel. Only certain types of blockages are amenable to stent placement, though drug-eluting stents may be successful in lesions for which bare-metal stents were insufficient. Drug-eluting stents are used to reopen grafts from prior CABG surgery that have themselves become blocked, and also can be used for in-stent restenosis in prior stents.<ref name="NEJM review" /> There has been considerable research showing the benefits of coronary stents. Data specifically on drug-eluting stents are less abundant, though where studied, they have usually been shown to be superior to bare-metal stents, and in some cases, may be used for lesions for which surgery was previously the only option. Drug-eluting stents are used both for restoring blood flow immediately after a heart attack and also electively for improving blood flow in a compromised vessel. Only certain types of blockages are amenable to stent placement, though drug-eluting stents may be successful in lesions for which bare-metal stents were insufficient. Drug-eluting stents are used to reopen grafts from prior CABG surgery that have themselves become blocked, and also can be used for in-stent restenosis in prior stents.<ref name="NEJM review" />


==Current research== ==Curr]ent research==
Research focuses on establishing the roles for drug-eluting stents and for developing new types of stents. Different materials for all three components—the scaffolding, the carrier, and the drug—are being actively investigated. Research focuses on establishing the roles for drug-eluting stents and for developing new types of stents. Different materials for all three components—the scaffolding, the carrier, and the drug—are being actively investigated.


Line 90: Line 90:
}}</ref> In contrast, its Xience stent uses a durable (non-bioabsorbale) polymer on a cobalt stent.<ref name="Guidant Xience">{{cite web }}</ref> In contrast, its Xience stent uses a durable (non-bioabsorbale) polymer on a cobalt stent.<ref name="Guidant Xience">{{cite web
| url = http://www.guidant.com/news/500/web_release/nr_000551.shtml| title = Guidant News Release — June 22, 2005| accessdate = 2006-07-23 | url = http://www.guidant.com/news/500/web_release/nr_000551.shtml| title = Guidant News Release — June 22, 2005| accessdate = 2006-07-23
| date = 2005-06-22| publisher = ] | date = ]| publisher = ]
}}</ref> }}</ref>



Revision as of 18:21, 23 July 2006

An example of a drug-eluting stent. This is the TAXUS™ Express™ Paclitaxel-Eluting Coronary Stent System, which releases paclitaxel.

In medicine, a drug-eluting stent is a stent (a metal scaffold) placed into diseased coronary arteries that slowly releases a drug blocking cell proliferation; this helps to delay or prevent the artery from being re-occluded by smooth muscle and clot (thrombus). The stent consists of a expandable metal framework, a drug to prevent restenosis, and a carrier to slowly release the drug. It is placed over a balloon on a catheter and guide wire and introduced through a peripheral artery, usually one of the femoral arteries. It is threaded back towards the heart; from the aorta, the appropriate coronary artery is entered. The balloon is inflated, cracking and compressing the plaque and expanding the stent. The balloon and catheter are then withdrawn, leaving the stent in place. The stent releases its drug over the next several months. Patients must take antiplatelet therapy afterwards, usually clopidogrel for six months and aspirin indefinitely. Drug-eluting stents have been shown to be superior for many of the conditions that traditional stents (“bare-metal stents”) have been used; they have been highly successful at treating coronary heart disease, and offer significant advantages over other therapies. In the few years since their FDA approval in 2003, the use of drug-eluting stents has become one of the dominant interventions in preventing and treating heart attacks.

Current devices

Currently, two models of drug-eluting stents are used. Both drugs currently in use are previously developed drugs used for other purposes; their use to prevent in-stent proliferation is relatively new.

The first successful type releases sirolimus (rapamycin), a powerful immunosuppressive and antiproliferative drug. It is primarily used as an immunosuppressant to prevent organ transplant rejection. Produced by the bacterium Streptomyces hygroscopicus, binds to the immunophilin FKBP-12. The resulting complex inhibits the mammalian target of rapamycin (mTOR), which has several effects, including preventing the cell from duplicating its genetic material; it blocks the cell cycle at the G1→S transition. A sirolimus-eluting stent is produced by Cordis Corporation (Johnson & Johnson), and marketed under the name Cypher. This stent is made of stainless steel and uses a polymer as the carrier.

A second model uses paclitaxel, another antiproliferative drug; it is primarily used against various forms of cancer. Derived from the yew tree, paclitaxel binds to and stabilizes microtubules. Without the dynamic framework provided by these components of the cytoskeleton, the cell cannot undergo mitosis and so is arrested at the M stage. The paclitaxel-eluting stent produced by Boston Scientific is marketed under the name Taxus. Like the Cypher stent, the Taxus stent is made of stainless steel and uses a polymer as drug carrier.

History

Diagram of stent placement. In A, the catheter is inserted across the lesion. In B, the balloon is inflated, expanding the stent and compressing the plaque. In C, the catheter and deflated balloon have been removed. Before-and-after cross sections of the artery show the results of the stent placement.

Heart attacks, or myocardial infarctions, are major causes of death and disability; they result when a portion of heart muscle dies from inadequate blood flow. This typically occurs at sites where coronary arteries are already narrowed and damaged. If blood flow can be restored early enough, permanent damage can be prevented, and preemptive restoration can prevent heart attacks from occurring in the first place. The first procedural method to perform a type of open-heart surgery called coronary artery bypass graft (CABG) surgery, which uses a section of vein or artery from elsewhere in the body to bypass the diseased vessel. In 1977, Andreas Grüntzig introduced percutaneous transluminal coronary angioplasty (PTCA), in which a catheter was introduced through a peripheral artery and a balloon expanded to compress and crack the obstructive plaque.

As equipment and techniques improved, the use of PTCA rapidly increased, and by the mid-1980s, PTCA and CABG were being performed at equivalent rates.. PTCA could only be used on limited scenarios, and the vessels had a high rate (30–40% in six months) of restenosis; additionally, 3% required emergency bypass surgery.. Dotter and Judkins had suggested using intraluminal prosthetic devices to maintain blood flow (in arteries of the leg) in 1964, and in 1986, Puel and Sigwart implanted the first stent in humans. Several trials in the 1990s showed the superiority of stent placement to simple balloon angioplasty, and stent placement became increasingly prevalent, reaching 84% of percutaneous interventions by 1999.

Initial difficulties included blood clotting and occluding the stent in the hours or days after placement. Coating the stent with biologically inert substances like platinum or gold did not help. Eventually, using high balloon pressures to tightly fix the stent against the vessel and anticoagulation with aspirin and (usually) clopidogrel were established; these eliminated most of the difficulty with in-stent thrombosis.

Difficulties still remained, however, with the formation of scar tissue inside the stent (in-stent neointimal hyperplasia) and clotting problems not addressed by the antiplatelet drug regimen. The stent itself was a logical choice for delivering medication. The slow release of drugs from the stent spares the patient the inconvenience of taking yet another medication, and prevents the danger of the patient forgetting to take or losing interest in taking the medicine. But more importantly, a stent that releases a drug can deliver high concentrations directly to the target region, analagous to placing a medicated cream on a skin problem or taking an inhaler to help the lungs or airways. Taking the medication orally or intravenously would require much higher doses as it was distributed throughout the body to ensure that a sufficient concentration would be reached at the target; this could cause unacceptable side effects or patient injury.

The first successful trials were of sirolimus-eluting stents. A successful trial in 2002 led to approval of the Cypher stent in Europe, followed by FDA approval in the U.S. in 2003. Soon thereafter, a series of trials of paclitaxel-eluting stents led to FDA approval of the Taxus stent in 2004.

Uses

There has been considerable research showing the benefits of coronary stents. Data specifically on drug-eluting stents are less abundant, though where studied, they have usually been shown to be superior to bare-metal stents, and in some cases, may be used for lesions for which surgery was previously the only option. Drug-eluting stents are used both for restoring blood flow immediately after a heart attack and also electively for improving blood flow in a compromised vessel. Only certain types of blockages are amenable to stent placement, though drug-eluting stents may be successful in lesions for which bare-metal stents were insufficient. Drug-eluting stents are used to reopen grafts from prior CABG surgery that have themselves become blocked, and also can be used for in-stent restenosis in prior stents.

CurrLink titleent research

Research focuses on establishing the roles for drug-eluting stents and for developing new types of stents. Different materials for all three components—the scaffolding, the carrier, and the drug—are being actively investigated.

In place of the stainless steel currently used in stents, various biodegradable frameworks are under early phases of investigation. Since metal, as a foreign substance, provokes inflammation, scarring, and thrombosis (clotting), it is hoped that biodegradable or bioabsorbable stents may prevent some of these effects. A magnesium alloy–based stent has been tested in animals, though there is currently no carrier for drug elution. A promising biodegradable framework is made from poly-L-lactide, a polymer of a derivative of L-lactic acid. One of these stents, the Igaki-Tamai stent, has been studied in pigs; tranilast and paclitaxel have been used as eluted drugs.

There are also several other anti-proliferative drugs under investigationin human clinical trials. In general, these are analogues of sirolimus. Like sirolimus, these block the action of mTOR. Abbott has developed zotarolimus; unlike sirolimus and paclitaxel, this sirolimus analogue designed for use in stents with phosphorylcholine as a carrier. Their ZoMaxx stent is a zotarolimus-eluting, stainless steel and tantalum–based stent; a modified phosphorylcholine slowly releases the zotarolimus. Zotarolimus has been licensed to Medtronic who is researching the effectiveness in a drug-eluting stent of their own. Their Endeavor stent also uses phosphorylcholine to carry the zotarolimus; the stent is a cobalt alloy. The Endeavor stent was approved for use in Europe in 2005.

Clinical trials are currently examining two stents carrying everolimus, an immunosuppressant that like sirolimus is used to prevent organ rejection. Guidant, which has the exclusive license to use everolimus in drug-eluting stents, is the manufacturer of both stents. The Champion stent uses a bioabsorbable polylactic acid carrier on a stainless steel stent. In contrast, its Xience stent uses a durable (non-bioabsorbale) polymer on a cobalt stent.

Complications and controversy

In the last several years, drug-eluting stent use has become exceedingly popular, both in place of surgery and for lesions not severe enough for surgery. Placing stents is not without risk, however, and the recent development of the drug-eluting stents means that long-term data, especially in comparison to traditional bare-metal stents, are not available. As enthusiasm for the new devices abates, there is some concern about overzealous use of stents in general.

As with all cardiac catheterization, there are several risks. Patients may exhibit severe allergic response to the contrast agents used to visualize the coronary arteries, and occasionally, the peripheral entry artery fails to properly heal after the catheter is removed, causing a collection of blood called a hematoma. Rarely, a coronary artery can be perforated while the catheter is advanced or during stent placement.

Finally, stent occlusion can occur. Thrombosis may occur during the procedure, in the following days, or much later. Stents cause damage to the vessel wall, and, as foreign objects, they provoke inflammation and clot formation. And tissue proliferation in the stent can cause the vessel to narrow again. Patients with stents (but not those undergoing isolated balloon angioplasty) must remain on an antiplatelet drug like clopidogrel for at least three to six months; discontinuing it, even for a short time, can cause a clot to form; aspiring must be taken for life. Drug-eluting stents have been shown to have significantly lower rates of in-stent proliferation compared to bare-metal stents. However, some studies suggest that the proliferation may be merely delayed; when the drug has been completely eluted, proliferation may occur. The magnitude and significance of this effect is unclear. Rarely, a type of allergic reaction to the drug may occur; episodes of fatality have been reported.

Nevertheless, coronary stents, and drug-eluting stents in particular, have revolutionized the treatment of coronary heart disease, and new techniques and materials that may ameliorate these problems are being studied. Bioabsorble or biodegradable polymer or stent may help avoid the inflammation and other side effects of long-term foreign objects. Different carriers affect the rate of release of drug, and different antiproliferative drugs may have different clinical effects. The success of drug-eluting stents in coronary disease has prompted investigation of their use in other narrowed arteries, such as the carotid arteries leading to the brain. Such use remains investigational.

References

  1. Michel, Thomas (2006) . "Treatment of Myocardial Ischemia". In Laurence L. Brunton, John S. Lazo, & Keith L. Parker (ed.). Goodman & Gilman's The Pharmacological Basis of Therapeutics (11th ed. ed.). New York: McGraw-Hill. p. 842. {{cite book}}: |edition= has extra text (help)CS1 maint: multiple names: editors list (link)
  2. ^ Serruys, Patrick W. (2006-02-02). "Coronary-Artery Stents". New England Journal of Medicine. 354 (5): 483–495. PMID 16452560. {{cite journal}}: Check date values in: |date= (help); Unknown parameter |coauthors= ignored (|author= suggested) (help) (extract)
  3. ^ "New Device Approval — Cypher Sirolimus-eluting Coronary Stent". Food and Drug Administration. Retrieved 2006-07-22.
  4. ^ Krensky, Alan M. (2006) . "Immunosuppressants, Tolerogens, and Immunostimulants". In Laurence L. Brunton, John S. Lazo, & Keith L. Parker (ed.). Goodman & Gilman's The Pharmacological Basis of Therapeutics (11th ed. ed.). New York: McGraw-Hill. p. 1413. {{cite book}}: |edition= has extra text (help); Unknown parameter |coauthors= ignored (|author= suggested) (help)CS1 maint: multiple names: editors list (link)
  5. Chabner, Bruce A. (2006) . "Antineoplastic Agents". In Laurence L. Brunton, John S. Lazo, & Keith L. Parker (ed.). Goodman & Gilman's The Pharmacological Basis of Therapeutics (11th ed. ed.). New York: McGraw-Hill. pp. 1352–1353. {{cite book}}: |edition= has extra text (help); Unknown parameter |coauthors= ignored (|author= suggested) (help)CS1 maint: multiple names: editors list (link)
  6. ^ "New Device Approval — P030025 — TAXUS™ Express™ Paclitaxel-Eluting Coronary Stent System". Food and Drug Administration. 2004-09-09. Retrieved 2006-07-22. {{cite web}}: Check date values in: |date= (help)
  7. Grüntzig, AR (1979-07-12). "Nonoperative dilatation of coronary-artery stenosis: percutaneous transluminal coronary angioplasty". New England Journal of Medicine. 301 (2): 61–68. PMID 449946. Retrieved 2006-07-22. {{cite journal}}: Check date values in: |date= (help); Unknown parameter |coauthors= ignored (|author= suggested) (help) (abstract)
  8. ^ Baim, Donald S. (2005) . "Percutaneous Coronary Revascularization". In Dennis L. Kasper, Anthony S. Fauci, Dan L. Longo, Eugene Braunwald, Stephen L. Hauser, & J. Larry Jameson (ed.). Harrison's Principles of Internal Medicine (16th ed. ed.). New York: McGraw-Hill. pp. 1459–1462. {{cite book}}: |edition= has extra text (help)CS1 maint: multiple names: editors list (link)
  9. Dotter, Charles T. (1964). "Transluminal Treatment of Arteriosclerotic Obstruction". Circulation. 30: 654–670. PMID 14226164. Retrieved 2006-07-22. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help) (abstract)
  10. Heublein, B. (2003). "Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?". Heart. 89: 651–656. PMID 12748224. Retrieved 2006-07-23. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  11. Tsuji, T. (2003). "Biodegradable stents as a platform to drug loading". International Journal of Cardiovascular Interventions. 5 (1): 13–6. PMID 12623560. {{cite journal}}: |access-date= requires |url= (help); Unknown parameter |coauthors= ignored (|author= suggested) (help)
  12. Vogt, Felix (2004). "Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent". European Heart Journal. 25: 1330–1340. PMID 15288161. Retrieved 2006-07-22. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  13. "Vascular Devices". Abbott. Retrieved 2006-07-23.
  14. Grube, Eberhard (2004). "Six- and Twelve-Month Results From First Human Experience Using Everolimus-Eluting Stents With Bioabsorbable Polymer". Circulation. 109: 2168–2171. doi:10.1161/01.CIR.0000128850.84227.FD. PMID 15123533. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  15. "Guidant News Release — April 5, 2004". Guidant. 2004-04-05. Retrieved 2007-07-23. {{cite web}}: Check date values in: |date= (help)
  16. "Guidant News Release — June 22, 2005". Guidant. 2005-06-22. Retrieved 2006-07-23. {{cite web}}: Check date values in: |date= (help)
  17. Virmani, Renu (2004). "Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent". Circulation. 109: 701–706. doi:10.1161/01.CIR.0000116202.41966.D4. PMID 14744976. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  18. Boulos, A. S. (2005). "Preliminary evidence supporting the safety of drug-eluting stents in neurovascular disease". Neurological Research. 27 Suppl 1: S95–102. PMID 16197833. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)