Revision as of 18:37, 28 September 2018 edit207.47.204.134 (talk)No edit summary← Previous edit | Revision as of 23:25, 28 September 2018 edit undoWerdna (talk | contribs)Extended confirmed users6,655 edits Correct definition of D value - it is the value required to kill 90% of organisms, not 100%.Tag: Visual editNext edit → | ||
Line 1: | Line 1: | ||
In ], '''D-value''' refers to '''decimal reduction time''' (or decimal reduction dose) and is the time (or dose) required at a given condition (e.g. temperature), or set of conditions, to kill |
In ], '''D-value''' refers to '''decimal reduction time''' (or decimal reduction dose) and is the time (or dose) required at a given condition (e.g. temperature), or set of conditions, to kill 90% (or 1 log) of the exposed ]<ref>{{Cite web|url=https://www.fda.gov/iceci/inspections/inspectionguides/ucm070835.htm|title=Inspection Guides - Sterilizing Symbols (D, Z, F)|last=U.S. Food and Drug Administration|first=|date=|website=www.fda.gov|language=en|archive-url=|archive-date=|dead-url=|access-date=2018-09-28}}</ref>. The term originated from assessing microbial thermal resistance and ] analysis; however, it has analogous uses in other microbial resistance and death rate applications, such as (but not limited to) those of ] and ] processing. | ||
Thus after a colony is reduced by 1 D, only 10% of the original organisms remain, i.e., the population number has been reduced by one decimal place in the counting scheme. Generally, each lot of a ]-resistant organism is given a unique D-value. When referring to D-values, for the purpose of thermal analysis, it is proper to give the temperature as a subscript of the "D". For example, given a hypothetical organism which is reduced by 90% after exposure to temperatures of 150° ] for 20 minutes, the D-value would be written as D<sub>150C</sub> = 20 minutes. If generally describing D-value for any temperature, a common abbreviation is D<sub>T</sub> (where T is temperature) until a value for T is relevant to express, specifically. Another more general abbreviated expression of D-value is D<sub>10</sub> (as to denote 10% reduction). | Thus after a colony is reduced by 1 D, only 10% of the original organisms remain, i.e., the population number has been reduced by one decimal place in the counting scheme. Generally, each lot of a ]-resistant organism is given a unique D-value. When referring to D-values, for the purpose of thermal analysis, it is proper to give the temperature as a subscript of the "D". For example, given a hypothetical organism which is reduced by 90% after exposure to temperatures of 150° ] for 20 minutes, the D-value would be written as D<sub>150C</sub> = 20 minutes. If generally describing D-value for any temperature, a common abbreviation is D<sub>T</sub> (where T is temperature) until a value for T is relevant to express, specifically. Another more general abbreviated expression of D-value is D<sub>10</sub> (as to denote 10% reduction). |
Revision as of 23:25, 28 September 2018
In microbiology, D-value refers to decimal reduction time (or decimal reduction dose) and is the time (or dose) required at a given condition (e.g. temperature), or set of conditions, to kill 90% (or 1 log) of the exposed microorganisms. The term originated from assessing microbial thermal resistance and thermal death time analysis; however, it has analogous uses in other microbial resistance and death rate applications, such as (but not limited to) those of ethylene oxide and radiation processing.
Thus after a colony is reduced by 1 D, only 10% of the original organisms remain, i.e., the population number has been reduced by one decimal place in the counting scheme. Generally, each lot of a sterilization-resistant organism is given a unique D-value. When referring to D-values, for the purpose of thermal analysis, it is proper to give the temperature as a subscript of the "D". For example, given a hypothetical organism which is reduced by 90% after exposure to temperatures of 150° C for 20 minutes, the D-value would be written as D150C = 20 minutes. If generally describing D-value for any temperature, a common abbreviation is DT (where T is temperature) until a value for T is relevant to express, specifically. Another more general abbreviated expression of D-value is D10 (as to denote 10% reduction).
D-value determination is sometimes carried out to measure a disinfectant's efficiency to reduce the number of microbes present in a given environment.
See also
References
- U.S. Food and Drug Administration. "Inspection Guides - Sterilizing Symbols (D, Z, F)". www.fda.gov. Retrieved 2018-09-28.
{{cite web}}
: Cite has empty unknown parameter:|dead-url=
(help) - Priscila Gava Mazzola, Thereza Christina Vessoni Penna, Alzira M da S Martins (17 October 2003). "Determination of decimal reduction time (D value) of chemical agents used in hospitals for disinfection purposes". BMC Infectious Diseases. 3: 24. doi:10.1186/1471-2334-3-24.
{{cite journal}}
: CS1 maint: multiple names: authors list (link) CS1 maint: unflagged free DOI (link)
This microbiology-related article is a stub. You can help Misplaced Pages by expanding it. |