Category 6 cable, commonly referred to as Cat 6, is a standardized cable for Gigabit Ethernet and other network physical layers that is backward compatible with the Category 5/5e and Category 3 cable standards. Compared with Cat 5 and Cat 5e, Cat 6 features more stringent specifications for crosstalk and system noise. The cable standard provides performance of up to 250 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet).

Whereas Category 6 cable has a reduced maximum length when used for 10GBASE-T; Category 6a cable, (or Augmented Category 6), is characterized to 500 MHz and has improved alien crosstalk characteristics, allowing 10GBASE-T to be run for the same distance as previous protocols.

The heavier wire in some Cat 6 cables makes them too thick to attach to standard 8P8C connectors without a special modular piece, resulting in a technically out-of-compliance assembly. Because the conductor sizes are generally the same, Cat 6 jacks may also be used with Cat 5e cable.

Category 6 cable can be identified by the printing on the side of the cable sheath.

Cat 6 patch cables are normally terminated in 8P8C modular connectors. If Cat 6 rated patch cables, jacks and connectors are not used with Cat 6 wiring, overall performance is degraded to that of the cable or connector.

Connectors use either T568A or T568B pin assignments; although performance is comparable provided both ends of a cable are the same.

Pin T568A Pair T568B Pair Wire T568A Color T568B Color Pins on plug face (socket is reversed)
1 3 2 tip Pair 3 Tip
white/green stripe
Pair 2 Tip
white/orange stripe
2 3 2 ring Pair 3 Ring
green solid
Pair 2 Ring
orange solid
3 2 3 tip Pair 2 Tip
white/orange stripe
Pair 3 Tip
white/green stripe
4 1 1 ring Pair 1 Ring
blue solid
Pair 1 Ring
blue solid
5 1 1 tip Pair 1 Tip
white/blue stripe
Pair 1 Tip
white/blue stripe
6 2 3 ring Pair 2 Ring
orange solid
Pair 3 Ring
green solid
7 4 4 tip Pair 4 Tip
white/brown stripe
Pair 4 Tip
white/brown stripe
8 4 4 ring Pair 4 Ring
brown solid
Pair 4 Ring
brown solid
Note: This is from left to right, with the plastic latching tab facing away from the viewer.


Category 6a

The latest standard from the TIA for enhanced performance standards for twisted pair cable systems was defined in February 2009 in ANSI/TIA-568-C.1. Category 6a is defined at frequencies up to 500 MHz—twice that of Cat. 6.

Category 6a performs at improved specifications, in particular in the area of alien crosstalk as compared to Cat 6 UTP (unshielded twisted pair), which exhibited high alien noise in high frequencies.

The global cabling standard ISO/IEC 11801 has been extended by the addition of amendment 2. This amendment defines new specifications for Cat. 6A components and Class EA permanent links. These new global Cat. 6A/Class EA specifications require a new generation of connecting hardware offering far superior performance compared to the existing products that are based on the American TIA standard.

The most important point is a performance difference between ISO/IEC and EIA/TIA component specifications for the NEXT transmission parameter. At a frequency of 500 MHz, an ISO/IEC Cat. 6A connector performs 3 dB better than a Cat. 6A connector that conforms with the EIA/TIA specification. 3 dB equals 50% reduction of near-end crosstalk noise signal power; see 3dB-point.

Confusion therefore arises because of the different naming conventions and performance benchmarks laid down by the International ISO/IEC and American TIA/EIA standards, which in turn are different from the regional European standard, EN 50173-1. In broad terms, the ISO standard for Cat6A is the highest, followed by the European standard and then the American (1 on 1 matching capability).

Maximum length

When used for 10/100/1000BASE-T, the maximum allowed length of a Cat 6 cable is 100 meters or 328 feet. This consists of 90 meters (300 ft) of solid "horizontal" cabling between the patch panel and the wall jack, plus 10 meters (33 ft) of stranded patch cable between each jack and the attached device. Since stranded cable has higher attenuation than solid cable, exceeding 10 meters of patch cabling will reduce the permissible length of horizontal cable.

When used for 10GBASE-T, Cat 6 cable's maximum length is 55 meters (180 ft) in a favorable alien crosstalk environment, but only 37 meters (121 ft) in a hostile alien crosstalk environment, such as when many cables are bundled together. However, because the effects of alien crosstalk environments on cables are difficult to determine prior to installation, it is highly recommended that all Cat6 cables used for 10GBASE-T be electrically tested once installed. With its improved specifications, Cat6A does not have this limitation and can run 10GBASE-T at 100 meters (330 ft) without electronic testing.

Installation caveats

Category 6 and 6a cable must be properly installed and terminated to meet specifications. The cable must not be kinked or bent too tightly (the bend radius should be at least four times the outer diameter of the cable). The wire pairs must not be untwisted and the outer jacket must not be stripped back more than 0.5 in (1.27 cm).

Cable shielding may be required in order to improve a Cat 6 cable's performance in high electromagnetic interference (EMI) environments. This shielding reduces the corrupting effect of EMI on the cable's data. Shielding is typically maintained from one cable end to the other using a drain wire that runs through the cable alongside the twisted pairs. The shield's electrical connection to the chassis on each end is made through the jacks. The requirement for ground connections at both cable ends creates the possibility that a ground loop may result if one of the networked chassis is at different instantaneous electrical potential with respect to its mate. This undesirable situation may compel currents to flow between chassis through the network cable shield, and these currents may in turn induce detrimental noise in the signal being carried by the cable.

Category 6e

Following the finalization of Cat 6, a number of manufacturers began offering "Category 6e" cables as an enhancement to the Category 6 standard—presumably naming it after Category 5e. However, no legitimate Category 6e standard exists, and Cat 6e is not a recognized standard by the Telecommunications Industry Association.

While all Cat 6e cables presumably meet Category 6 standards, the actual increase in transfer speeds and the maximum cable length varies from manufacturer to manufacturer owing largely to the lack of an industry standard.

See also

References

  1. ^ Kish, Paul (July 2002). "Category 6 Cabling Questions and Answers" (PDF). NORDX/CDT, Inc. Retrieved 21 October 2013.
  2. Ethernet Cable Identification and Use
  3. ^ "A new Category 6A specification has arrived". Next generation Cat. 6A. Tyco Electronics. Retrieved 2011-03-22.
  4. "Cat. 6A ≠ Cat. 6 A ≠ Class EA". Next generation Cat. 6A. Tyco Electronics. Retrieved 2011-03-22.
  5. Cabling: The Complete Guide to Network Wiring, 3rd Edition
  6. "Category 5 / 5E & Cat 6 Cabling Tutorial and FAQ's". LANshack.com. Retrieved 2012-01-06.
  7. Cat 6e vs Cat 6a

External links

Unshielded and shielded twisted pair cabling standards
Categories
See also
Copper cable certification
Ethernet over twisted pair
Modular connector
TIA/EIA-568
Twisted pair