This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed. Find sources: "Digital Data Storage" – news · newspapers · books · scholar · JSTOR (February 2013) (Learn how and when to remove this message) |
This article provides insufficient context for those unfamiliar with the subject. Please help improve the article by providing more context for the reader. (August 2021) (Learn how and when to remove this message) |
Media type | Magnetic cassette tape |
---|---|
Encoding | Lossless real-time |
Read mechanism | Rotating head |
Write mechanism | Rotating head, helical scan |
Developed by | Sony |
Usage | Data storage |
Extended from | Digital Audio Tape |
Released | 1989; 35 years ago (1989) |
Digital Data Storage (DDS) is a computer data storage technology that is based upon the Digital Audio Tape (DAT) format that was developed during the 1980s. DDS is primarily intended for use as off-line storage, especially for generating backup copies of working data.
Design
A DDS cartridge uses tape with a width of 3.81mm, with the exception of the latest formats, DAT-160 and DAT-320, both which use 8mm wide tape. Initially, the tape was 60 meters (197 feet) or 90 meters (295 ft.) in length. Advancements in materials technology have allowed the length to be increased significantly in successive versions. A DDS tape drive uses helical scan recording, the same process used by a video cassette recorder (VCR).
Backward compatibility between newer drives and older cartridges is not assured; the compatibility matrices provided by manufacturers will need to be consulted. Typically drives can read and write tapes in the prior generation format, with most (but not all) also able to read and write tapes from two generations prior. Notice in HP's article that newer tape standards do not simply consist of longer tapes; with DDS-2, for example, the track was narrower than with DDS-1.
At one time, DDS competed against the Linear Tape-Open (LTO), Advanced Intelligent Tape (AIT), VXA, and Travan formats. However, AIT, Travan and VXA are no longer mainstream, and the capacity of LTO has far exceeded that of the most recent DDS standard, DDS-320.
History
This section is in list format but may read better as prose. You can help by converting this section, if appropriate. Editing help is available. (August 2021) |
- DDS-1
- Stores up to 1.3 GB uncompressed (2.6 GB compressed) on a 60 m cartridge or 2 GB uncompressed (4 GB compressed) on a 90 m cartridge. The DDS-1 cartridge often does not have the -1 designation, as initially it was the only format, though cartridges produced since the introduction of DDS-2 may carry a -1 designation to distinguish the format from newer formats. A media recognition system was introduced with DDS-2 drives and cartridges to detect the medium type and prevent the loading of an improper medium. From 1993, DDS-1 tapes included the media recognition system marks on the leader tape—a feature indicated by the presence of four vertical bars after the DDS logo.
- DDS-2
- Stores up to 4 GB uncompressed (8 GB compressed) on a 120 m cartridge.
- DDS-3
- Stores up to 12 GB uncompressed (24 GB compressed) on a 125 m cartridge. DDS-3 uses PRML (Partial Response Maximum Likelihood) to minimize electronic noise for a cleaner data recording.
- DDS-4
- DDS-4 stores up to 20 GB uncompressed (40 GB compressed) on a 150 m cartridge. This format is also called DAT 40.
- DAT 72
- DAT 72 stores up to 36 GB uncompressed (72 GB compressed) on a 170 m cartridge. The DAT 72 standard was developed by HP and Certance. It has the same form-factor as DDS-3 and -4 and is sometimes referred to as DDS-5.
- DAT 160
- DAT 160 was launched in June 2007 by HP, stores up to 80 GB uncompressed (160 GB compressed). A major change from the previous generations is the width of the tape. DAT 160 uses 8 mm wide tape in a slightly thicker cartridge while all prior versions use 3.81 mm wide tape. Despite the difference in tape widths, DAT 160 drives can load DAT-72 and DAT-40 (DDS-4) cartridges. Native capacity is 80 GB and native transfer rate was raised to 6.9 MB/s, mostly due to prolonging head/tape contact to 180° (compared to 90° previously). Launch interfaces were Parallel SCSI and USB, with SAS interface released later.
- DAT 320
- In November 2009 HP announced the DAT-320 standard, which stores up to 160 GB uncompressed (marketed as 320 GB assuming 2:1 compression) per cartridge. Native transfer rate was raised to 12 MB/s.
Generations
Format | Date | Tape width (mm) |
Track pitch (μm) |
Tape length (m) |
Native capacity (GB) |
Capacity assuming 2:1 compression (GB) |
Drum rotation speed (RPM) |
Data transfer speed (MB/s) |
---|---|---|---|---|---|---|---|---|
DDS-1 | 1989 | 3.81 | 13.6 | 60/90 | 1.3/2.0 | 2.6/4 | 2000, 2551 | 0.183 |
DDS-2 | 1993 | 3.81 | 9.1 | 120 | 4.0 | 8 | 4000, 4400, 5737, 8500 | 0.360-0.720 |
DDS-3 | 1996 | 3.81 | 9.1 | 125 | 12.0 | 24 | 3825, 4252 | <1.5 |
DDS-4 | 1999 | 3.81 | 6.8 | 150 | 20.0 | 40 | 11400 | 1.0-3.2 |
DAT-72 | 2003 | 3.81 | 5.4 | 170 | 36.0 | 72 | 8609.7, 10000 | 3.2 |
DAT-160 | 2007 | 8 | 6.8 | 154 | 80 | 160 | 6457 | 6.9 |
DAT-320 | 2009 | 8 | 153 | 160 | 320 | 12 | ||
(Gen 8) | canceled | 8 | ~300 | ~600 | ≥16 |
Future
The next format, Gen 8, was canceled.
See also
References
- Compatibility matrix for: HP, IBM
- "DAT Technology". DAT Manufacturers Group. Archived from the original on 2013-05-31. Retrieved 2013-03-31.
{{cite web}}
: CS1 maint: bot: original URL status unknown (link) - "HP DAT 320 320GB Data Cartridge - DAT & DDS tape cartridges - HP: Q2032A". Hewlett-Packard. Archived from the original on 2014-01-01. Retrieved 2013-12-31.
External links
- DAT Manufacturers Group
- ECMA-139 ISO/IEC 10777:1991, Specification of DDS. ECMA-139
- ECMA-146 ISO/IEC 11321:1992, Specification of DATA/DAT. ECMA-146
- ECMA-150 ISO/IEC 11557:1992, Specification of DDS-DC (DDS w/ compression). ECMA-150
- ECMA-151 ISO/IEC 11558:1992, Specification of DCLZ (compression algorithm). ECMA-151
- ECMA-170 ISO/IEC 12447:1993, Specification of DDS (for 60m and 90m tapes). ECMA-170
- ECMA-171 ISO/IEC 12448:1993, Specification of DATA/DAT-DC (for 60m and 90m tapes). ECMA-171
- ECMA-198 ISO/IEC 13923, Specification of DDS-2. ECMA-198
- ECMA-236 ISO/IEC 15521, Specification of DDS-3. ECMA-236
- ECMA-288 ISO/IEC 17462, Specification of DDS-4. ECMA-288
Magnetic-tape data storage formats | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Linear |
| ||||||||||||
Helical |
|
Standards of Ecma International | ||
---|---|---|
Application interfaces | ||
File systems (tape) |
| |
File systems (disk) | ||
Graphics | ||
Programming languages | ||
Radio link interfaces | ||
Other | ||
List of Ecma standards (1961 – present) |