Misplaced Pages

Bragg peak

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
(Redirected from Bragg Peak)

Path length of maximum energy loss of ionizing radiation For use of this term to describe diffraction peaks, also known as reflections, see Bragg reflection.
This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Bragg peak" – news · newspapers · books · scholar · JSTOR (September 2014) (Learn how and when to remove this message)
The Bragg curve of 5.49 MeV alphas in air has its peak to the right and is skewed to the left, unlike the x-ray beam below.

The Bragg peak is a pronounced peak on the Bragg curve which plots the energy loss of ionizing radiation during its travel through matter. For protons, α-rays, and other ion rays, the peak occurs immediately before the particles come to rest. It is named after William Henry Bragg, who discovered it in 1903 using alpha particles from radium, and wrote the first empirical formula for ionization energy loss per distance with Richard Kleeman.

When a fast charged particle moves through matter, it ionizes atoms of the material and deposits a dose along its path. A peak occurs because the interaction cross section increases as the charged particle's energy decreases. Energy lost by charged particles is inversely proportional to the square of their velocity, which explains the peak occurring just before the particle comes to a complete stop. In the upper figure, it is the peak for alpha particles of 5.49 MeV moving through air. In the lower figure, it is the narrow peak of the "native" proton beam curve which is produced by a particle accelerator of 250 MeV. The figure also shows the absorption of a beam of energetic photons (X-rays) which is entirely different in nature; the curve is mainly exponential.

The dose produced by a native and by a modified proton beam in passing through tissue, compared to the absorption of a photon or x-ray beam

This characteristic of proton beams was first recommended for use in cancer therapy by Robert R. Wilson in his 1946 article, Radiological Use of Fast Protons. Wilson studied how the depth of proton beam penetration could be controlled by the energy of the protons. This phenomenon is exploited in particle therapy of cancer, specifically in proton therapy, to concentrate the effect of light ion beams on the tumor being treated while minimizing the effect on the surrounding healthy tissue.

The blue curve in the figure ("modified proton beam") shows how the originally monoenergetic proton beam with the sharp peak is widened by increasing the range of energies, so that a larger tumor volume can be treated. The plateau created by modifying the proton beam is referred to as the spread out Bragg Peak, or SOBP, which allows the treatment to conform to not only larger tumors, but to more specific 3D shapes. This can be achieved by using variable thickness attenuators like spinning wedges. Momentum cooling in cyclotron-based proton therapy facilities enables a sharper distal fall-off of the Bragg peak and the attainment of high dose rates.

See also

References

  1. Charlie Ma, C-M; Lomax, Tony (2012). Proton and carbon ion therapy. Boca Raton: CRC Press. p. 4. ISBN 9781439816073.
  2. Bragg, W. H. (1904). "LXXIII. On the absorption of α rays, and on the classification of the α rays from radium". The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science. 8(48): 719–725. doi:10.1080/14786440409463245.
  3. Bragg, William Henry; Kleeman, Richard (1905). "XXXIX. On the α particles of radium, and their loss of range in passing through various atoms and molecules" (PDF). The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science. 10:57: 318-340. doi:10.1080/14786440509463378.
  4. "Bragg Curves and Peaks". Brookhaven National Laboratory. Retrieved 27 January 2016.
  5. Wilson, Robert R. (1946-11-01). "Radiological Use of Fast Protons". Radiology. 47 (5): 487–491. doi:10.1148/47.5.487. ISSN 0033-8419. PMID 20274616.
  6. Trikalinos, TA; et al. (2009). Particle Beam Radiation Therapies for Cancer [Internet]. Comparative Effectiveness Technical Briefs, No. 1. Rockville (MD): Agency for Healthcare Research and Quality (US). pp. ES1–ES5.
  7. Jette, D.; Chen, W. (2011). "Creating a spread-out Bragg peak in proton beams". Physics in Medicine and Biology. 56 (11): N131-8. doi:10.1088/0031-9155/56/11/N01. PMID 21558588. S2CID 37517481.
  8. Paganetti, Harald; Bortfeld, Thomas. "Proton Beam Radiotherapy - The State of the Art1" (PDF). AAPM. p. 16. Retrieved 27 January 2016.
  9. Maradia, V., Meer, D., Dölling, R. et al. Demonstration of momentum cooling to enhance the potential of cancer treatment with proton therapy. Nat. Phys. (2023). https://doi.org/10.1038/s41567-023-02115-2.

External links

Categories: