(Redirected from Decirad) Non-SI unit measuring absorbed dose of ionizing radiation "Rad (unit)" redirects here. Not to be confused with Rad (angular unit).
rad
Unit systemCGS units
Unit ofAbsorbed dose of ionizing radiation
Symbolrad
Conversions
1 rad in ...... is equal to ...
   SI base units   0.01 Jkg
   SI units   0.01 Gy
   CGS   100 erg/g

The rad is a unit of absorbed radiation dose, defined as 1 rad = 0.01 Gy = 0.01 J/kg. It was originally defined in CGS units in 1953 as the dose causing 100 ergs of energy to be absorbed by one gram of matter. The material absorbing the radiation can be human tissue, air, water, or any other substance.

It has been replaced by the gray (symbol Gy) in SI derived units, but is still used in the United States, although this is "strongly discouraged" in Chapter 5.2 of the Guide to the SI, which was written and published by the U.S. National Institute of Standards and Technology. However, the numerically equivalent SI unit submultiple, the centigray (symbol cGy), is widely used to report absorbed doses within radiotherapy. The roentgen, used to quantify the radiation exposure, may be related to the corresponding absorbed dose by use of the F-factor.

Health effects

Main article: Acute radiation syndrome

A dose of under 100 rad will typically produce no immediate symptoms other than blood changes. A dose of 100 to 200 rad delivered to the entire body in less than a day may cause acute radiation syndrome (ARS), but is usually not fatal. Doses of 200 to 1,000 rad delivered in a few hours will cause serious illness, with poor prognosis at the upper end of the range. Whole body doses of more than 1,000 rad are almost invariably fatal. Therapeutic doses of radiation therapy are often given and tolerated well even at higher doses to treat discrete, well-defined anatomical structures. The same dose given over a longer period of time is less likely to cause ARS. Dose thresholds are about 50% higher for dose rates of 20 rad/h, and even higher for lower dose rates.

The International Commission on Radiological Protection maintains a model of health risks as a function of absorbed dose and other factors. That model calculates an effective radiation dose, measured in units of rem, which is more representative of the stochastic risk than the absorbed dose in rad. In most power plant scenarios, where the radiation environment is dominated by X- or gamma rays applied uniformly to the whole body, 1 rad of absorbed dose gives 1 rem of effective dose. In other situations, the effective dose in rem might be thirty times higher or thousands of times lower than the absorbed dose in rad.

Dose examples (metric prefixed unit multiples)
25 rad:  Lowest dose to cause clinically observable blood changes
200 rad:  Local dose for onset of erythema in humans
400 rad:  Whole body LD50 for acute radiation syndrome in humans
1 krad:  Whole body LD100 for acute radiation syndrome in humans
1–20 krad:  Typical radiation tolerance of ordinary microchips
4–8 krad:  Typical radiotherapy dose, locally applied
10 krad:  Fatal whole-body dose in 1964 Wood River Junction criticality accident
1 Mrad:  Typical tolerance of radiation-hardened microchips


SI multiples of rad (rad)
Submultiples Multiples
Value SI symbol Name Value SI symbol Name
10 rad drad decirad 10 rad darad decarad
10 rad crad centirad 10 rad hrad hectorad
10 rad mrad millirad 10 rad krad kilorad
10 rad μrad microrad 10 rad Mrad megarad
10 rad nrad nanorad 10 rad Grad gigarad
10 rad prad picorad 10 rad Trad terarad
10 rad frad femtorad 10 rad Prad petarad
10 rad arad attorad 10 rad Erad exarad
10 rad zrad zeptorad 10 rad Zrad zettarad
10 rad yrad yoctorad 10 rad Yrad yottarad
10 rad rrad rontorad 10 rad Rrad ronnarad
10 rad qrad quectorad 10 rad Qrad quettarad

History

In the 1930s the roentgen was the most commonly used unit of radiation exposure. This unit is obsolete and no longer clearly defined. One roentgen deposits 0.877 rad in dry air, 0.96 rad in soft tissue, or anywhere from 1 to more than 4 rad in bone depending on the beam energy. These conversions to absorbed energy all depend on the ionizing energy of a standard medium, which is ambiguous in the latest NIST definition. Even where the standard medium is fully defined, the ionizing energy is often not precisely known.

In 1940, British physicist Louis Harold Gray, who had been studying the effect of neutron damage on human tissue, together with William Valentine Mayneord and John Read published a paper in which a unit of measure, dubbed the "gram roentgen" (symbol: gr) defined as "that amount of neutron radiation which produces an increment in energy in unit volume of tissue equal to the increment of energy produced in unit volume of water by one roentgen of radiation" was proposed. This unit was found to be equivalent to 88 ergs in air. It marked a shift towards measurements based on energy rather than charge.

The Röntgen equivalent physical (rep), introduced by Herbert Parker in 1945, was the absorbed energetic dose to tissue before factoring in relative biological effectiveness. The rep has variously been defined as 83 or 93 ergs per gram of tissue (8.3/9.3 mGy) or per cc of tissue.

In 1953 the ICRU recommended the rad, equal to 100 erg/g as a new unit of absorbed radiation, but then promoted a switch to the gray in the 1970s.

The International Committee for Weights and Measures (CIPM) has not accepted the use of the rad. From 1977 to 1998, the US NIST's translations of the SI brochure stated that the CIPM had temporarily accepted the use of the rad (and other radiology units) with SI units since 1969. However, the only related CIPM decisions shown in the appendix are with regards to the curie in 1964 and the radian (symbol: rad) in 1960. The NIST brochures redefined the rad as 0.01 Gy. The CIPM's current SI brochure excludes the rad from the tables of non-SI units accepted for use with the SI. The US NIST clarified in 1998 that it was providing its own interpretations of the SI system, whereby it accepted the rad for use in the US with the SI, while recognizing that the CIPM did not. NIST recommends defining the rad in relation to SI units in every document where this unit is used. Nevertheless, use of the rad remains widespread in the US, where it is still an industry standard. Although the United States Nuclear Regulatory Commission still permits the use of the units curie, rad, and rem alongside SI units, the European Union required that its use for "public health ... purposes" be phased out by 31 December 1985.

Radiation-related quantities

The following table shows radiation quantities in SI and non-SI units:

Ionizing radiation related quantities
Quantity Unit Symbol Derivation Year SI equivalent
Activity (A) becquerel Bq s 1974 SI unit
curie Ci 3.7×10 s 1953 3.7×10 Bq
rutherford Rd 10 s 1946 1000000 Bq
Exposure (X) coulomb per kilogram C/kg C⋅kg of air 1974 SI unit
röntgen R esu / 0.001293 g of air 1928 2.58×10 C/kg
Absorbed dose (D) gray Gy J⋅kg 1974 SI unit
erg per gram erg/g erg⋅g 1950 1.0×10 Gy
rad rad 100 erg⋅g 1953 0.010 Gy
Equivalent dose (H) sievert Sv J⋅kg × WR 1977 SI unit
röntgen equivalent man rem 100 erg⋅g × WR 1971 0.010 Sv
Effective dose (E) sievert Sv J⋅kg × WR × WT 1977 SI unit
röntgen equivalent man rem 100 erg⋅g × WR × WT 1971 0.010 Sv

See also

References

  1. International Bureau of Weights and Measures (2008). United States National Institute of Standards and Technology (ed.). The International System of Units (SI) (PDF). NIST Special Publication 330. Dept. of Commerce, National Institute of Standards and Technology. Retrieved September 1, 2018.
  2. "NIST Guide to SI Units – ch.5.2 Units temporarily accepted for use with the SI". National Institute of Standards and Technology.
  3. The Effects of Nuclear Weapons, Revised ed., US DOD 1962, pp. 592–593
  4. "The 2007 Recommendations of the International Commission on Radiological Protection". Annals of the ICRP. ICRP publication 103. 37 (2–4). 2007. ISBN 978-0-7020-3048-2. Retrieved 17 May 2012.
  5. "Converting rad to rem, Health Physics Society ". Archived from the original on June 26, 2013.
  6. Anno, GH; Young, RW; Bloom, RM; Mercier, JR (2003). "Dose response relationships for acute ionizing-radiation lethality". Health Physics. 84 (5): 565–575. doi:10.1097/00004032-200305000-00001. PMID 12747475. S2CID 36471776.
  7. Goans, R E; Wald, N (1 January 2005). "Radiation accidents with multi-organ failure in the United States". British Journal of Radiology: 41–46. doi:10.1259/bjr/27824773.
  8. Introduction to Radiation-Resistant Semiconductor Devices and Circuits
  9. "APPENDIX E: Roentgens, RADs, REMs, and other Units". Princeton University Radiation Safety Guide. Princeton University. Retrieved 10 May 2012.
  10. Sprawls, Perry. "Radiation Quantities and Units". The Physical Principles of Medical Imaging, 2nd Ed. Retrieved 10 May 2012.
  11. Gupta, S. V. (2009-11-19). "Louis Harold Gray". Units of Measurement: Past, Present and Future : International System of Units. Springer. p. 144. ISBN 978-3-642-00737-8. Retrieved 2012-05-14.
  12. Cantrill, S.T; H.M. Parker (1945-01-05). "The Tolerance Dose". Argonne National Laboratory: US Atomic Energy Commission. Archived from the original on November 30, 2012. Retrieved 14 May 2012. {{cite journal}}: Cite journal requires |journal= (help)
  13. Dunning, John R.; et al. (1957). A Glossary of Terms in Nuclear Science and Technology. American Society of Mechanical Engineers. Retrieved 14 May 2012.
  14. Bertram, V. A. Low-Beer (1950). The clinical use of radioactive isotopes. Thomas. Retrieved 14 May 2012.
  15. Guill, JH; Moteff, John (June 1960). "Dosimetry in Europe and the USSR". Third Pacific Area Meeting Papers - Materials in Nuclear Applications - American Society Technical Publication No 276. Symposium on Radiation Effects and Dosimetry - Third Pacific Area Meeting American Society for Testing Materials, October 1959, San Francisco, 12–16 October 1959. Baltimore: ASTM International. p. 64. LCCN 60-14734. Retrieved 15 May 2012.
  16. International Bureau of Weights and Measures (1977). United States National Bureau of Standards (ed.). The international system of units (SI). NBS Special Publication 330. Dept. of Commerce, National Bureau of Standards. p. 12. Retrieved 18 May 2012.
  17. The International System of Units (PDF) (9th ed.), International Bureau of Weights and Measures, Dec 2022, ISBN 978-92-822-2272-0
  18. Lyons, John W. (1990-12-20). "Metric System of Measurement: Interpretation of the International System of Units for the United States". Federal Register. 55 (245). US Office of the Federal Register: 52242–52245.
  19. Hebner, Robert E. (1998-07-28). "Metric System of Measurement: Interpretation of the International System of Units for the United States" (PDF). Federal Register. 63 (144). US Office of the Federal Register: 40339. Retrieved 9 May 2012.
  20. Handbook of Radiation Effects, 2nd edition, 2002, Andrew Holmes-Siedle and Len Adams
  21. 10 CFR 20.1004. US Nuclear Regulatory Commission. 2009.
  22. The Council of the European Communities (1979-12-21). "Council Directive 80/181/EEC of 20 December 1979 on the approximation of the laws of the Member States relating to Unit of measurement and on the repeal of Directive 71/354/EEC". Retrieved 19 May 2012.
Systems of measurement
Current
General
Specific
Natural
Background
Metric
UK/US
Historic
Metric
Europe
Asia
Africa
North America
South America
Ancient
List articles
Other
Radiation protection
Main articles
Measurement
quantities and units
Instruments and
measurement techniques
Protection techniques
Organisations
Regulation
Radiation effects
See also the categories Medical physics, Radiation effects, Radioactivity, Radiobiology, and Radiation protection
Categories: