Misplaced Pages

Emergency disconnect package

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
This article has multiple issues. Please help improve it or discuss these issues on the talk page. (Learn how and when to remove these messages)
This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Emergency disconnect package" – news · newspapers · books · scholar · JSTOR (February 2024) (Learn how and when to remove this message)
The topic of this article may not meet Misplaced Pages's general notability guideline. Please help to demonstrate the notability of the topic by citing reliable secondary sources that are independent of the topic and provide significant coverage of it beyond a mere trivial mention. If notability cannot be shown, the article is likely to be merged, redirected, or deleted.
Find sources: "Emergency disconnect package" – news · newspapers · books · scholar · JSTOR (September 2012) (Learn how and when to remove this message)
(Learn how and when to remove this message)

An Emergency Disconnect Package (EDP) is a piece of equipment used in the drilling and work-over (servicing or modification) of deep sea oil & gas wells, by Mobile Offshore Drilling Rigs (MODU's) and Well Intervention Vessels (WIV's). The EDP is designed for use in an emergency, when the MODU or WIV needs to quickly disconnect, and move away from the oil/gas well that it is drilling or working-over. Examples of when this might be necessary include unexpected extreme weather that exceeds the MODU/Vessel's capability to maintain its position.

Under normal operating conditions, the MODU/WIV (which is floating on the sea surface) is connected to the oil/gas well (which is drilled in the sea bed) by a vertical (or near-vertical) piece of steel pipe, called a marine riser. Tools and fluids are moved within the marine riser as required to/from the well. At the bottom of the marine riser, the EDP and other components that connect the riser to the well and allow the well to be shut-in when required, constitute a 'Lower Riser Package' (LRP).

When required to do so, the EDP disconnects from the LRP and isolates the riser from the environment. Thus the EDP allows the MODU/WIV to safely and quickly disconnect from the subsea well and move away in an emergency. The EDP is designed to carry out its function while under load with a high disconnection angle.

An EDP consists of a connector to the rest of the LRP, an isolation valve, an accumulator, a subsea control module and a connection point at the top for connection to the riser pipe. A production retainer valve shuts in the riser and the annulus master valve shuts in the riser. A crossover valve allows circulation of the riser after disconnection. <refs. IADC Drilling Lexicon / API RP 17G, Recommended Practice for Completion/Workover Risers / API RP 96, Deepwater Well Design and Construction / GSO Engineering>