Misplaced Pages

Henry adsorption constant

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
Ratio of the concentration of an adsorbate onto a solid to its partial pressure in the gas phase

The Henry adsorption constant is the constant appearing in the linear adsorption isotherm, which formally resembles Henry's law; therefore, it is also called Henry's adsorption isotherm. It is named after British chemist William Henry. This is the simplest adsorption isotherm in that the amount of the surface adsorbate is represented to be proportional to the partial pressure of the adsorptive gas:

X = K H P {\displaystyle X=K_{H}P}

where:

  • X - surface coverage,
  • P - partial pressure,
  • KH - Henry's adsorption constant.

For solutions, concentrations, or activities, are used instead of the partial pressures.

The linear isotherm can be used to describe the initial part of many practical isotherms. It is typically taken as valid for low surface coverages, and the adsorption energy being independent of the coverage (lack of inhomogeneities on the surface).

The Henry adsorption constant can be defined as:

K H = lim ϱ 0 ϱ s ϱ ( z ) , {\displaystyle K_{H}=\lim _{\varrho \rightarrow 0}{\frac {\varrho _{s}}{\varrho (z)}},}

where:

  • ϱ ( z ) {\displaystyle \varrho (z)} is the number density at free phase,
  • ϱ s {\displaystyle \varrho _{s}} is the surface number density,

Application at a permeable wall

Source:

If a solid body is modeled by a constant field and the structure of the field is such that it has a penetrable core, then

K H = x [ exp ( β u ) exp ( β u 0 ) ] d x x [ 1 exp ( β u ) ] d x . {\displaystyle K_{H}=\int \limits _{-\infty }^{x'}{\big }dx-\int \limits _{x'}^{\infty }{\big }dx.}

Here x {\displaystyle x'} is the position of the dividing surface, u = u ( x ) {\displaystyle u=u(x)} is the external force field, simulating a solid, u 0 {\displaystyle u_{0}} is the field value deep in the solid, β = 1 / k B T {\displaystyle \beta =1/k_{B}T} , k B {\displaystyle k_{B}} is the Boltzmann constant, and T {\displaystyle T} is the temperature.

Introducing "the surface of zero adsorption"

x 0 = 0 θ ~ ( x ) d x + 0 φ ~ ( x ) d x , {\displaystyle x_{0}=-\int \limits _{-\infty }^{0}{\widetilde {\theta }}(x)dx+\int \limits _{0}^{\infty }{\widetilde {\varphi }}(x)dx,}

where

θ ~ = exp ( β u ) exp ( β u 0 ) 1 exp ( β u 0 ) {\displaystyle {\widetilde {\theta }}={\frac {\exp {(-\beta u)}-\exp {(-\beta u_{0})}}{1-\exp {(-\beta u_{0})}}}}

and

φ ~ = 1 exp ( β u ) 1 exp ( β u 0 ) , {\displaystyle {\widetilde {\varphi }}={\frac {1-\exp {(-\beta u)}}{1-\exp {(-\beta u_{0})}}},}

we get

K H ( x ) = [ x x 0 ( T ) ] [ 1 exp ( β u 0 ) ] {\displaystyle K_{H}(x')=}

and the problem of K H {\displaystyle K_{H}} determination is reduced to the calculation of x 0 {\displaystyle x_{0}} .

Taking into account that for Henry absorption constant we have

k H = lim ϱ 0 ϱ ( z ) ϱ ( z ) = exp ( β u 0 ) , {\displaystyle k_{H}=\lim _{\varrho \rightarrow 0}{\frac {\varrho (z')}{\varrho (z)}}=\exp(-\beta u_{0}),}

where ϱ ( z ) {\displaystyle \varrho (z')} is the number density inside the solid, we arrive at the parametric dependence

K H = x [ k H u ~ ( x ) k H ] d x x [ 1 k H u ~ ( x ) ] d x {\displaystyle K_{H}=\int \limits _{-\infty }^{x'}{\big }dx-\int \limits _{x'}^{\infty }{\big }dx}

where

u ~ ( x ) = u ( x ) u 0 . {\displaystyle {\widetilde {u}}(x)={\frac {u(x)}{u_{0}}}.}

Application at a static membrane

Source:

If a static membrane is modeled by a constant field and the structure of the field is such that it has a penetrable core and vanishes when x = ± {\displaystyle x=\pm \infty } , then

K H = [ exp ( β u ) 1 ] d x . {\displaystyle K_{H}=\int \limits _{-\infty }^{\infty }{\big }dx.}

We see that in this case the K H {\displaystyle K_{H}} sign and value depend on the potential u {\displaystyle u} and temperature only.

Application at an impermeable wall

Source:

If a solid body is modeled by a constant hard-core field, then

K H = x exp ( β u ) d x x [ 1 exp ( β u ) ] d x , {\displaystyle K_{H}=\int \limits _{-\infty }^{x'}\exp(-\beta u)dx-\int \limits _{x'}^{\infty }{\big }dx,}

or

K H ( x ) = x x 0 ( T ) , {\displaystyle K_{H}(x')=x'-x_{0}(T),}

where

x 0 = 0 θ ( x ) d x + 0 φ ( x ) d x . {\displaystyle x_{0}=-\int \limits _{-\infty }^{0}\theta (x)dx+\int \limits _{0}^{\infty }\varphi (x)dx.}

Here

θ = exp ( β u ) {\displaystyle \theta =\exp {(-\beta u)}}
φ = 1 exp ( β u ) . {\displaystyle \varphi =1-\exp {(-\beta u)}.}

For the hard solid potential

x 0 = x s t e p , {\displaystyle x_{0}=x_{step},}

where x s t e p {\displaystyle x_{step}} is the position of the potential discontinuity. So, in this case

K H ( x ) = x x s t e p . {\displaystyle K_{H}(x')=x'-x_{step}.}

Choice of the dividing surface

Sources:

The choice of the dividing surface, strictly speaking, is arbitrary, however, it is very desirable to take into account the type of external potential u ( x ) {\displaystyle u(x)} . Otherwise, these expressions are at odds with the generally accepted concepts and common sense.

First, x {\displaystyle x'} must lie close to the transition layer (i.e., the region where the number density varies), otherwise it would mean the attribution of the bulk properties of one of the phase to the surface.

Second. In the case of weak adsorption, for example, when the potential is close to the stepwise, it is logical to choose x {\displaystyle x'} close to x 0 {\displaystyle x_{0}} . (In some cases, choosing x 0 ± R {\displaystyle x_{0}\pm R} , where R {\displaystyle R} is particle radius, excluding the "dead" volume.)

In the case of pronounced adsorption it is advisable to choose x {\displaystyle x'} close to the right border of the transition region. In this case all particles from the transition layer will be attributed to the solid, and K H {\displaystyle K_{H}} is always positive. Trying to put x = x 0 {\displaystyle x'=x_{0}} in this case will lead to a strong shift of x {\displaystyle x'} to the solid body domain, which is clearly unphysical.

Conversely, if u 0 < 0 {\displaystyle u_{0}<0} (fluid on the left), it is advisable to choose x {\displaystyle x'} lying on the left side of the transition layer. In this case the surface particles once again refer to the solid and K H {\displaystyle K_{H}} is back positive.

Thus, except in the case of static membrane, we can always avoid the "negative adsorption" for one-component systems.

See also

References

  1. H. Yıldırım Erbil, "Surface Chemistry of Solid And Liquid Interfaces", Blackwell Publishing, 2006.(google books)
  2. ^ Zaskulnikov V. M., Statistical mechanics of fluids at a permeable wall: arXiv:1111.0082
  3. ^ Zaskulnikov V. M., Statistical mechanics of fluids at an impermeable wall: arXiv:1005.1063
Categories: