Scalar control of an AC electrical motor is a way to achieve the variable speed operation by manipulating the supply voltage or current ("magnitude") and the supply frequency while ignoring the magnetic field orientation inside the motor. Scalar control is based on equations valid for a steady-state operation and is frequently open-loop (no sensing except for the current limiter). The scalar control has been to a large degree replaced in high-performance motors by vector control that enables better handling of the transient processes. Low cost and simplicity keeps the scalar control in the majority of low-performance motors, despite inferiority of its dynamic performance; vector control is expected to become universal in the future.

Types

The variants of the scalar control include open-loop control and closed-loop control.

Open-loop

The most common approach makes the voltage V proportional to frequency f (so called V/f control, V/Hz control, Constant Volts/Hertz, CVH). Advantage of the V/f variant is in keeping the magnetic flux inside the stator constant thus maintaining the motor performance across the range of speeds. A voltage boost at low frequencies is typically employed to compensate for the resistance of the coils.

An open-loop V/f control works well in applications with near-constant load torque and gradual changes in rotational speed. The controllers implementing this method are sometimes called general purpose AC drives.

Closed-loop

If sensors are utilized (closed-loop configuration) for better/faster transitional response, the common approach uses a rotational speed sensor (so called closed-loop V/Hz control). The speed error is passed through the proportional-integral controller to create the accumulated slip difference that is combined with the direct reading of the speed sensor into a frequency control signal.

In a torque-control variant (TC, not to be confused with the direct torque control a.k.a. DTC), the motor torque is held constant in the steady-state, this requires a current sensor. Frequency and flux (voltage or current, depending on the type of the drive) control signals are decoupled, with the flux control driven by the flux estimate, and the frequency control driven by the torque estimate and speed sensor data. The increased performance comes at the cost of additional complexity and associated potential stability issues.

References

  1. ^ Finch & Giaouris 2008, p. 483.
  2. Buja & Kazmierkowski 2004, p. 744.
  3. ^ Trzynadlowski 2013, p. 43.
  4. Bose 2009, p. 11.
  5. ^ Chan & Shi 2011, p. 3.
  6. Bose 2002, p. 340.
  7. Bose 2002, pp. 342–344.
  8. With the current feedback in place, the motor can be driven using either a voltage-fed inverter or a current-fed inverter.