The thermal manikin is a human model designed for scientific testing of thermal environments without the risk or inaccuracies inherent in human subject testing. Thermal manikins are primarily used in automotive, indoor environment, outdoor environment, military and clothing research. The first thermal manikins in the 1940s were developed by the US Army and consisted of one whole-body sampling zone. Modern-day manikins can have over 30 individually controlled zones. Each zone (right hand, pelvis, etc.) contains a heating element and temperature sensors within the “skin” of the manikin. This allows the control software to heat the manikin to a normal human body temperature, while logging the amount of power necessary to do so in each zone and the temperature of that zone.
History
Clothing insulation is the thermal insulation provided by clothing and it is measured in clo. The measuring unit was developed in 1941. Shortly afterward, thermal manikins were developed by the US Army for the purposes of carrying out insulation measurements on the gear they were developing. The first thermal manikins were standing, made of copper, and were one segment, measuring whole-body heat loss. Over the years these were improved upon by various companies and individuals employing new technologies and techniques as understanding of thermal comfort increased. In the mid-1960s, seated and multi-segmented thermal manikins were developed, and digital regulation was employed, allowing for much more accurate power application and measurement. Over time breathing, sneezing, moving (such as continuous walking or biking motions) and sweating were all employed in the manikins, in addition to male, female, and child sizes depending on the application. Nowadays most manikins used for research purposes will have a minimum of 15 zones, and as many as 34 with options (often as a purchasable add-on to the base manikin) for sweating, breathing, and movement systems although simpler manikins are also in use in the clothing industry. Additionally, in the early 2000s several different computer models of manikins were developed in Hong Kong, the UK, and Sweden.
The following table gives an overview of different thermal manikin developments through the years:
Type | Material | Measurement Method | Adjustability | Development location and time |
---|---|---|---|---|
One-segment | Copper | Analogue | – | US 1945 |
Multi-segment | Aluminium | Analogue | – | UK 1964 |
Radiation manikin | Aluminium | Analogue | – | France 1972 |
Multi-segment | Plastics | Analogue | Movable | Denmark 1973 |
Multi-segment | Plastics | Analogue | Movable | Germany 1978 |
Multi-segment | Plastics | Digital | Movable | Sweden 1980 |
Multi-segment | Plastics | Digital | Movable | Sweden 1984 |
Fire manikin | Aluminium | Digital | – | US |
Immersion manikin | Aluminium | Digital | Movable | Canada 1988 |
Sweating manikin | Aluminium | Digital | – | Japan 1988 |
Plastic | Digital | Movable | Finland 1988 | |
Aluminium | Digital | Movable | USA 1996 | |
Female manikin | Plastics | Digital, comfort regulation mode | Movable | Denmark 1989 |
Single wire | ||||
Breathing thermal manikin | Plastics | Digital, comfort regulation mode | Movable, breathing simulation | Denmark 1996 |
Single wire | ||||
Sweating manikin | Plastic | Digital, 30 dry and 125 sweat zones | Realistic movements | Switzerland 2001 |
Self-contained, sweating field manikin | Metal | Digital, 126 zones | Articulated | USA 2003 |
Virtual, computer manikin | Numerical, geometric model | Heat and mass transfer simulations | Articulated | China 2000 |
Numerical, geometric model | Heat and mass transfer simulations | Articulated | UK 2001 | |
Numerical, geometric model | Heat and mass transfer simulations | Articulated | Sweden 2001 | |
Numerical, geometric model | Heat and mass transfer simulations | Articulated | Japan 2002 | |
One-segment, sweating manikin | Breathable fabric | Digital, water heated | Movable | China 2001 |
One-segment manikin | Windproof fabric | Digital, air heated | Movable | USA 2003 |
Design
Modern thermal manikins consist of three main elements, with optional additional add-ons. The exterior skin of the manikin may be made of fiberglass, polyester, carbon fiber, or other heat conducting materials, within which are temperature sensors in each measurement zone. Underneath the skin is the heating element. Each zone of a thermal manikin is designed to be heated as evenly as possible. To achieve this, wiring is coiled throughout the interior of the manikin with as few gaps as possible. Electricity is run through the wire to heat it, with the power use of each zone being separate controlled and recorded by the manikin control software. Finally, the manikins are designed to simulate humans as accurately as possible, and so any necessary additional mass is added to the interior of the manikin and distributed as needed. Additionally, manikins may be fitted with supplemental devices that mimic human actions such as breathing, walking, or sweating.
The heating element of thermal manikins may be set up in one of three locations within the manikin: at the outer surface, within the skin of the manikin, or in the interior of the manikin. The further inside the manikin the heating element is, the more stable the heat output at the skin surface will be, however the time constant of the manikin’s ability to respond to changes in the external environment will also rise as it will take longer for heat to penetrate through the system.
Control
The amount of heat supplied to thermal manikins may be controlled in three ways. In “comfort mode” the PMV model equation found in ISO 7730 is applied to the manikin, and the controller software calculates the heat loss an average person would be comfortable undergoing within a given environment. This requires that the system know several basic facts about the manikin (surface area, hypothesized metabolic rate) while experimental factors must be input by the user (clothing insulation, Wet Bulb Globe Temperature). The second control method is constant heat flux from the manikin. That is, the manikin supplies a constant level of power, set by the user, and the skin temperature of the different segments is measured. The third method is that the skin temperature of the manikin is maintained constant at a user-specified value, while the power increases or decreases depending on the environmental conditions. This may arguably be considered a fourth method as well, as one can set the entire manikin to maintain the same temperature in all zones, or choose specific temperatures for each zone. Of these methods, the comfort mode is considered to be the most accurate representation of the actual heat distribution across the human body, while the heat flux mode is primarily used in high temperature settings (when room temperatures are likely to be above 34 °C).
Calibration
Temperature sensors
To obtain the most accurate results possible it is necessary to calibrate the internal temperature sensors of the thermal manikin. A good calibration will use at least 2 temperature set points minimum 10 °C apart from one another. The manikin is set up in a thermally controlled environmental chamber so that the temperature of all its segments will be nearly identical to the operative temperature of the chamber. This means that the manikin must be unclothed and with minimal insulation between any body part and the air. A good system to achieve this is to have the manikin seated in an open chair (allowing air movement to pass through), with its feet propped up off the ground. Fans should be used to increase air movement in the chamber, ensuring constant mixing. This is acceptable for maintaining a constant temperature as there is no evaporative cooling without sweating or condensation (humidity should be low to ensure no condensation occurs). At each temperature set point the manikin will need to remain in the room for 3 to 6 hours in order to come to steady state conditions. Once equilibrium has been obtained a calibration point may be obtained for each body segment (this should be included in the control software).
Equivalent temperature
The most accurate method of evaluating how the environment is affecting the thermal manikin is by calculating the equivalent temperature of the environment, accounting for the effects of radiant heat, air temperature, and air movement. It is necessary to calibrate the manikin based on this before each experiment, as the factor to convert power output and manikin skin temperature to equivalent temperature (the heat transfer coefficient) changes slightly for each zone of the manikin and based on clothing the manikin is wearing. Calibration should be carried out in a thermally controlled chamber, where radiant and air temperatures are nearly identical, and minimal temperature variation occurs throughout the space. It is necessary that the manikin be wearing the same clothing as it will during experimental tests. Multiple calibration points must be taken, minimally spanning the range of temperatures that will be tested in the experiment. During calibration air movement should be kept as low as possible, and as much of the manikin’s surface should be exposed to air and radiant heat as possible, by placing it on supports that keep it in a seated position but do not block the back or legs as a traditional seat would. Manikin data should be recorded for each calibration point when the air, surface, and manikin temperatures have all reached steady state. Temperature of the “seat” should also be recorded, and data collection should not be stopped before the seat has reached a steady state temperature. To calculate the heat transfer coefficient (hcali) the following equation is used:
hcali = Qsi/tski – teq
where:
- Qsi = the dry heat loss, or power, recorded by the manikin
- tski = the skin temperature of the manikin
- teq = the equivalent temperature of the room (the calibration temperature)
This factor may then be used to calculate equivalent temperature during further experiments in which radiant temperature and air velocity are not controlled using the equation:
teq = tski – Qsi/hcali
Setup
Posture, positioning, and clothing affect the thermal manikin measurements. With regard to posture, the most accurate method would be to have the manikin in precisely the same posture as it was calibrated in. Clothing affects heat transfer to the manikin and may add a layer of air insulation. Clothing reduces the effects of air velocity and changes the strength of the free convection flow around the body and face. Fitted clothing should be used if possible to decrease uncertainty of measurements as loose clothing is likely to change shape any time the manikin is moved.
References
- Gagge, Adolph Pharo; Burton, Alan Chadburn; Bazett, Henry Cuthbert (1941). "A practical system of units for the description of the heat exchange of man with his environment". Science. 94 (2445): 428–430. Bibcode:1941Sci....94..428G. doi:10.1126/science.94.2445.428. PMID 17758307.
- ^ Holmér, Ingvar (2004). "Thermal manikin history and applications". European Journal of Applied Physiology. 92 (6): 614–618. doi:10.1007/s00421-004-1135-0. PMID 15185083. S2CID 22961337.
- Li, Yi; Newton, Edward; Luo, Xiaonan; Luo, Zhongxuan (2000). "Integrated CAD for functional textiles and apparel". Proceedings of Nokobotef 6 and 1st European Conference on Protective Clothing. 8: 8–11.
- Fiala, Dusan; Lomas, Kevin; Stohrer, Martin (October 2001). "Computer prediction of human thermoregulatory and temperature responses to a wide range of environmental conditions". International Journal of Biometeorology. 45 (3): 143–59. Bibcode:2001IJBm...45..143F. doi:10.1007/s004840100099. PMID 11594634. S2CID 24476680.
- Nilsson, Håkan (December 2007). "Thermal comfort evaluation with virtual manikin methods". Building and Environment. 42 (12): 4000–40005. doi:10.1016/j.buildenv.2006.04.027.
- Tanabe, S.; Arens, E.A.; Bauman, F.S.; Zhang, H.; Madsen, T.L. (1994). "Evaluating thermal environments by using a thermal manikin with controlled skin surface temperature". ASHRAE Transactions. 100 (1): 39–48.
- ^ Melikov, Arsen (2004). "Breathing thermal manikins for indoor environment assessment: important characteristics and requirements". European Journal of Applied Physiology. 92 (6): 710–713. doi:10.1007/s00421-004-1142-1. PMID 15168126. S2CID 24765076.
- Thermal manikin calibration (PDF). Retrieved November 19, 2013.