Revision as of 20:00, 4 October 2006 editSimply south (talk | contribs)Autopatrolled, Extended confirmed users, Pending changes reviewers, Rollbackers31,984 edits 1500 V DC Overhead: corrected date← Previous edit Revision as of 13:17, 12 October 2006 edit undoPickle UK (talk | contribs)11,846 edits []Next edit →
Line 72: Line 72:
* ''']''' - converted from 6.25 kV AC overhead * ''']''' - converted from 6.25 kV AC overhead
* ''']''' - converted from 6.25K V AC overhead and 1500 V DC overhead * ''']''' - converted from 6.25K V AC overhead and 1500 V DC overhead
* ''']''' - in the 1980s * ''']''' - in the 1980s, including the ] and ] branches.
* ''']''' (south of Bedford) - in the 1980s * ''']''' (south of Bedford) - in the 1980s
* ''']''' - in the 1950s under the 1955 BR modernisation plan to Birmingham (new Street) / Liverpool (Lime Street) / Crewe / Manchester (Piccadilly). Extended in the 1970s to Glasgow. The ] was electrified by Network South East 1987-88. In 2003 Crewe to Kidsgrove section of the ] was electrified as a diversionary route for the WCML. * ''']''' - in the 1950s under the 1955 BR modernisation plan to Birmingham (new Street) / Liverpool (Lime Street) / Crewe / Manchester (Piccadilly). Extended in the 1970s to Glasgow.
**The ] was electrified by Network South East 1987-88.
**In 2003 Crewe to Kidsgrove section of the ] was electrified as a diversionary route for the WCML.
* '''Glasgow Suburban''' (see ] and ]) - started in the 1950s under the 1955 BR modernisation plan. * '''Glasgow Suburban''' (see ] and ]) - started in the 1950s under the 1955 BR modernisation plan.
* '''Leeds''' area - Leeds to Skipton (]), ] (]) and Leeds branch off the ECML (via ]) (1980s/early 1990s) * '''Leeds''' area - Leeds to Skipton (]), ] (]) and Leeds branch off the ECML (via ]) (1980s/early 1990s)
* '''Manchester''' area - ] (converted from the truncated 1,500V DC Manchester-Sheffield-Wath electric railway), the ] (although part of this line was converted to the Manchester Metrolink) and the ] (although primarily operated by diesel multiple units) * '''Manchester''' area - ] (converted from the truncated 1,500V DC Manchester-Sheffield-Wath electric railway), the ] (although part of this line was converted to the Manchester Metrolink) and the ] (although primarily operated by diesel multiple units)
* '''Birmingham''' area - ] and part of the ] (1980s/early 1990s) and branches into the West Midlands of the WCML * '''West Midlands''' area - A few lines out of ] mainly related to the West Coast Main Line.
**] - WCML, late 1950s.
**] - WCML, late 1950s.
**] - Electrified in the early 1990s, re-opening in 1993.
**] - Electrified from New Street to Walsal, in ???
* ''']''' (only between Heathrow and London Paddington - see ] and ]) * ''']''' (only between Heathrow and London Paddington - see ] and ])
* ''']''' - employing auto-transformers * ''']''' - employing auto-transformers

Revision as of 13:17, 12 October 2006

40% (3,062 miles / 4,928 km) of the British rail network is electrified and 60% of all rail journeys are by electric traction (both by locomotives and Multiple Units).

Railway electrification as a means of traction emerged at the end of the nineteenth century. It offered several benefits over the then predominate steam traction, particularly in respect of its quick acceleration (ideal for urban (metro) and suburban (commuter) services) and power (ideal for heavy freight trains through mountainous/hilly sections). A plethora of systems emerged in the first twenty years of the twentieth century (as listed below). In 1928 a government committee agreed 1500 V DC overhead as the national standard, although little work was done to implement this and the plethora of different systems continued to exist (and even expand). Post World War Two, with nationalisation (1948), British rail expanded electrification (1500 V DC and the Southern third rail) but soon (mid 1950s) adopted 25 KV AC overhead for its proposed mainline electrification. Over the years of minimal capital investment the 25 KV AC network has expanded although large areas of the country are still non electrified, despite their urban, suburban, hilly or intercity nature.

Rail based (Third and Fourth rails)

650 to 850 V DC Third rail

An example of third rail

630 V DC Fourth Rail

The Tube's 4th rail system
The Watford DC Line between Queens Park and Harrow & Wealdstone is peculiar in that it is used by both Silverlink Metro trains, designed for 750V third rail, and Bakerloo Line trains designed for 630V third and fourth rail. Consequently the voltage is set at a suitable compromise value around 690V nominal, and the centre rail is at the same potential as the return running rail, whereas in normal London Underground usage the traction supply floats with the centre rail at nominally -230V and the outer rail at nominally +420V. giving 630V overall.

1200 V DC Side Contact rail

A Class 504 (1200 V DC) train at Manchester Victoria station just weeks before closure for conversion to the Metrolink light rail system.
  • Manchester Victoria - Bury This very busy commuter line was electrified by the Lancashire and Yorkshire Railway in 1913 to 3500 V DC overhead (see above). In 1917 the L&YR converted it to side contact third rail. This system was abandoned when the line was converted to become part of the Manchester Metrolink. and

Overhead

1500 V DC Overhead

Tyne & Wear Metro is the only current 1500 V DC system in the UK

In the wake of World War One, the British Government set up a committee to investigate the various systems of railway electrification and in 1928 it reported that 1500 V DC overhead should be the future national standard. Several schemes (see below) were implemented in its wake, although the Great Depression and World War Two meant very little work was done. Technological advances post war saw a government U turn and the 25KV AC system was adopted instead for the West Coast Main line and Glasgow suburban electrification as set out in the 1955 BR modernisation plan - at the same time the large amounts of money had/were still being spent converting several lines to 1500 V DC.

  • Manchester, South Junction and Altrincham Railway - A joint LMS and LNER effort, opened on the 11th May 1931, it was a test bed for both companies for the new standard (which at the time had not been implemented in the UK) in this largely self-contained busy suburban line. The success of this scheme propelled LNER's latter electrification efforts. The line was latter converted to 25 KV AC in 1971 but then parts converted to the Manchester Metrolink (a tram system).
  • Manchester-Sheffield-Wath line. Known as the Woodhead Route. LNER, chose this hilly and busy mainline for its first mainline electrification, with work starting in 1936 . Due to the depression and World War Two it wasn't completed until the 1950s. However upon completion the government chose to utilise 25KV AC instead, leaving the few 1500v DC lines isolated and non-standard. Subsequent BR rationalisation (the Beeching Axe) saw large parts of this route closed east of Hadfield in 1981 (in favour of a route with more local communities). The remaining stub in Manchester was converted to 25 kV AC in December 1984.
  • Shenfield Metro (Great Eastern Main Line) - Electrified post war (early 1950s), although LNER had been planning this since the early 1930s. It was soon converted to 25 kV AC, initially with some sections at 6.25 kV, in wake the 1955 BR Modernisation plan.
  • Newport (near Sunderland) to Shildon (County Durham) line. In the wake of the electrification of Tyneside by the NER, this coal carrying line was electrified, as a precursor to electrifying NER's busy York to Newcastle mainline (Part of the ECML). It was dismantled by LNER around 1934/1935. , , , ,
  • Tyne and Wear Metro Despite the abandonment in favour of 25KV AC overhead in the 1950s, large parts of the former "Tyneside Electrics" routes (which had been electrified using third rail until the 1960s when BR discontinued the "non standard" equipment in favour of Diesels) were rebuilt as the "Tyne and Wear Metro" in the 1970s. Styled as "Light Rail" it is in practice normal heavy rail, and even shares some lines with the current rail network (unlike the other tram systems in the UK which operate alongside but on separate rights of way).

3500 V DC Overhead

  • Bury to Holcombe Brook This was electrified by the Lancashire and Yorkshire Railway in 1913 as part of a trial system for export. The system was converted thrid rail in 1917 (see above).

6600 V (6.6 kV) AC Overhead @25 Hz

6250 V (6.25 kV) AC Overhead @50 Hz

During the initial electrification of parts of the network to 25 kV AC overhead the initial solution to the limited clearance problems in suburban areas (due to numerous tunnels and bridges) - notably London and Glasgow - was to use the lower voltage of 6.25 kV AC Overhead. Latter technological improvements allowed these area to be converted to 25 kV AC Overhead.

25000 (25 kV) AC Overhead @50 Hz

The West Coast Main Line is electrified at 25 kV AC Overhead

See also

External links